Your browser doesn't support javascript.
loading
Primary Total Hip Arthroplasty With Ceramic-On-Ceramic Articulations: Analysis of a Single-Center Series of 1,083 Hips at a Minimum of 10-Year Follow-Up.
Niu, Erlong; Fu, Jun; Li, Hao; Ni, Ming; Hao, Libo; Zhou, Yonggang; Xu, Chi; Chen, Jiying.
Afiliação
  • Niu E; Medical School of Chinese PLA, Beijing, China; Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Beijing, China.
  • Fu J; Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Beijing, China; Senior Department of Orthopedics, Fourth Medical Center of PLA General Hospital, Beijing, China.
  • Li H; Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Beijing, China; Senior Department of Orthopedics, Fourth Medical Center of PLA General Hospital, Beijing, China.
  • Ni M; Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Beijing, China; Senior Department of Orthopedics, Fourth Medical Center of PLA General Hospital, Beijing, China.
  • Hao L; Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Beijing, China; Senior Department of Orthopedics, Fourth Medical Center of PLA General Hospital, Beijing, China.
  • Zhou Y; Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Beijing, China; Senior Department of Orthopedics, Fourth Medical Center of PLA General Hospital, Beijing, China.
  • Xu C; Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Beijing, China; Senior Department of Orthopedics, Fourth Medical Center of PLA General Hospital, Beijing, China.
  • Chen J; Department of Orthopedics, The First Medical Center of Chinese PLA General Hospital, Beijing, China; Senior Department of Orthopedics, Fourth Medical Center of PLA General Hospital, Beijing, China.
J Arthroplasty ; 38(8): 1539-1544, 2023 08.
Article em En | MEDLINE | ID: mdl-36529193
ABSTRACT

BACKGROUND:

There are limited long-term results of using ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) in a large number of patient cohorts. The purpose of this study was to evaluate the minimum 10-year clinical and radiological outcomes and survivorship in a single surgeon series of CoC-THA.

METHODS:

Among the 1,039 patients (1,391 hips) who underwent primary THA at our institution between 2008 and 2011, 49 patients (69 hips) experienced paralysis or death, and 194 patients (239 hips, 19%) were lost to follow-up. The remaining 796 patients (1,083 hips) were assessed at a mean of 11 years (range, 10 to 13 years) using the modified Harris hip score (mHHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and a questionnaire on articular noises. Survival analysis was used to estimate the survivorship. Radiological evaluation was performed on 869 hips at the final follow-up.

RESULTS:

Survivorship at 11 years was 98.3% for revision or aseptic loosening, and 98.2% for reoperation. At the final follow-up, the mean mHHS and WOMAC scores were 93 (range, 12 to 100) and 14.4 (range, 3 to 66), respectively. There were 131 (12%) hips that experienced squeaking, but no patient required revision. No fracture of the ceramic was observed. Radiological evaluation at the final follow-up revealed that 3 (0.3%) hips exhibited loosening, 2 (0.2%) had femoral osteolysis, 81(9.3%) acquired radiolucencies, and 35 (4%) showed heterotopic ossification.

CONCLUSION:

This CoC bearing for THA had a high survivorship and excellent functional outcomes for at least 10 years.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article