Your browser doesn't support javascript.
loading
HPLC-Fluorescence Detection Method for Concurrent Estimation of Domperidone and Naproxen. Validation and Eco-Friendliness Appraisal Studies.
Guirguis, Karin M; Zeid, May M; Shaalan, Rasha A; Belal, Tarek S.
Afiliação
  • Guirguis KM; Pharmaceutical Chemistry Department, Faculty of Pharmacy, Pharos University in Alexandria, Canal El-Mahmoudia, Alexandria, Egypt.
  • Zeid MM; Pharmaceutical Chemistry Department, Faculty of Pharmacy, Pharos University in Alexandria, Canal El-Mahmoudia, Alexandria, Egypt.
  • Shaalan RA; Pharmaceutical Chemistry Department, Faculty of Pharmacy, Pharos University in Alexandria, Canal El-Mahmoudia, Alexandria, Egypt. rasha.shaalan@pua.edu.eg.
  • Belal TS; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, University of Alexandria, Elmessalah, Alexandria, 21521, Egypt. rasha.shaalan@pua.edu.eg.
J Fluoresc ; 33(3): 945-954, 2023 May.
Article em En | MEDLINE | ID: mdl-36538143
This work demonstrates a simple and reliable HPLC method with fluorimetric detection for simultaneous estimation of domperidone (DOM) and naproxen (NAP). Successful chromatographic separation was accomplished using Inertsil ODS C18 column (5 µm, 4.6 × 150 mm) with gradient elution of the mobile phase consisting of 0.01 M phosphate buffer (pH 5.5) solution and acetonitrile. The gradient elution started with 25% acetonitrile increased linearly to 65% in 5 min, then kept at this percentage till the end of the run. The mobile phase was pumped at a flow rate of 1.0 mL/min. The excitation wavelength at 284 nm was found suitable for both DOM and NAP since it corresponds to a maximum for the minor component DOM and measurable excitation for NAP, while using 316 and 355 nm as emission wavelengths for DOM and NAP, respectively. Peaks eluted with excellent resolution at retention times 4.4 and 6.3 min for DOM and NAP, respectively. Performance of the proposed method was tested according to ICH guidelines in regard to linearity, ranges, precision, accuracy, robustness, detection and quantitation limits. Calibration curves were linear in the ranges of 0.8-3.6 and 1.0-2.5 µg/mL for DOM and NAP respectively with correlation coefficients not less than 0.9996. The validated method was successfully applied to the analysis of DOM and NAP in their laboratory prepared tablets resembling the commercial dosage form, and assay results were favorably compared with a published reference HPLC method. The method's greenness was assessed using the Analytical Eco-Scale and the novel Analytical Greenness metric (AGREE).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Naproxeno / Domperidona Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Naproxeno / Domperidona Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article