Your browser doesn't support javascript.
loading
Using an ultra-compact optical system to improve lateral flow immunoassay results quantitatively.
Chiu, Wei-Huai; Kong, Wei-Yi; Chueh, Yuan-Hui; Wen, Jyun-Wei; Tsai, Ciao-Ming; Hong, Chitsung; Chen, Pang-Yen; Ko, Cheng-Hao.
Afiliação
  • Chiu WH; Graduate Institute of Automation and Control, National Taiwan University of Science and Technology, Taipei, Taiwan.
  • Kong WY; Graduate Institute of Automation and Control, National Taiwan University of Science and Technology, Taipei, Taiwan.
  • Chueh YH; Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan.
  • Wen JW; SpectroChip Inc., Hsinchu, Taiwan.
  • Tsai CM; Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan.
  • Hong C; SpectroChip Inc., Hsinchu, Taiwan.
  • Chen PY; Department of Emergency Medicine, Mackay Memorial Hospital, Taipei, Taiwan.
  • Ko CH; Institute of Public Health, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Heliyon ; 8(12): e12116, 2022 Dec.
Article em En | MEDLINE | ID: mdl-36544820
ABSTRACT
The lateral flow immunoassay (LFIA) is a paper-based platform with extensive application in point-of-care (POC) testing and many fields. However, its clinical application is severely limited due to the lack of quantitative ability of standard LFIA tests; this augmentation provides the system with quantifying the signal from magenta-colored AuNPs. To address this issue, we proposed an ultra-compact optical system that allowed LFIAs to be performed more accurately and objectively. The experimental setup consisted of multiple optical accessories manufactured by 3D printing (STEP files were included). A high-resolution printer was used to print out a magenta card model for the LFIA, whose color code, ranging from 255, 255, 255 to 255, 0, 255 in the RGB (red, green, blue) format, represents different levels of magenta color intensity (from 0% to 100%) and thus the results of LFIA test strips. A mathematical model was built using a calibration curve to describe the relationship between magenta color value and reflectance spectrum. In addition, a spectrum module was integrated into the proposed system to identify and quantify LFIA results. This integration represents a pioneering step in developing portable detection techniques that facilitate quantifying LFIA results. Finally, we expect this ultra-compact optical spectroscopy system to have great potential for novel clinical applications.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article