Your browser doesn't support javascript.
loading
Issues in deep peak regulation for circulating fluidized bed combustion: Variation of NOx emissions with boiler load.
Ke, Xiwei; Zhu, Shahong; Huang, Zhong; Zhang, Man; Lyu, Junfu; Yang, Hairui; Zhou, Tuo.
Afiliação
  • Ke X; State Key Laboratory of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100089, China. Electronic address: kexiwei94@gmail.com.
  • Zhu S; Institute for Energy Engineering, China Jiliang University, Hangzhou 310018, China.
  • Huang Z; State Key Laboratory of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100089, China.
  • Zhang M; State Key Laboratory of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100089, China.
  • Lyu J; State Key Laboratory of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100089, China.
  • Yang H; State Key Laboratory of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100089, China.
  • Zhou T; State Key Laboratory of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100089, China. Electronic address: zhoutuo@mail.tsinghua.edu.cn.
Environ Pollut ; 318: 120912, 2023 Feb 01.
Article em En | MEDLINE | ID: mdl-36549451
ABSTRACT
In order to improve the consumption of renewable energies, certain amounts of circulating fluidized bed (CFB) boiler units should assume the task of deep peak regulation. However, the effect of CFB boiler load on pollutant emissions such as NOx still needs to be clarified. In this paper, the NOx emission characteristics of two industrial-scale CFB boilers within a wide load range (35%-100%) were further analyzed by using a comprehensive one-dimensional, two-phase CFB mathematical model. Simulation results reveal that, when the load ratio decreases, the NOx emission decreases first and then increases. The non-monotonic variation trend is also confirmed by the operational data collected from the SC-350 boiler. However, for different boilers, the load ratio corresponding to the turning point of NOx emission may be different, e.g., for the 135 MWe super high steam pressure boiler, it is about 40%, while for the 350 MWe supercritical boiler is 50%. On the one hand, the decrease in boiler load leads to a decline in the furnace temperature, which contributes to reducing NOx emission due to the decrease of volatile yields, the lower conversion rate of Vol-N to NOx, and the enhancement of the overall NO reduction on chars. On the other hand, at low loads, the excess air coefficient is generally set to high values, and air staging is weakened, resulting in adverse effects on the NOx emission control. In addition, when the CFB boiler operates at low loads, the solid circulation loop performance usually worsens, and the heat loss caused by incomplete combustion may increase. This study points out that high NOx emission is an unavoidable issue in the process of deep peak regulation for CFB boilers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Atmosféricos / Poluentes Ambientais Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Atmosféricos / Poluentes Ambientais Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article