Your browser doesn't support javascript.
loading
Accelerating the Laboratory Testing Capacity through Saliva Pooling Prior to Direct RT-qPCR for SARS-CoV-2 Detection.
Kaisar, Maria Mardalena Martini; Jonnatan, Sheila; Widowati, Tria Asri; Kristin, Helen; Vasandani, Suraj Rajan; Mahendra, Caroline; Ali, Soegianto.
Afiliação
  • Kaisar MMM; Master in Biomedicine Study Program, School of Medicine and Health Sciences, Atma Jaya Catholic University of Indonesia, Jakarta 14440, Indonesia.
  • Jonnatan S; Department of Parasitology, School of Medicine and Health Sciences, Atma Jaya Catholic University of Indonesia, Jakarta 14440, Indonesia.
  • Widowati TA; Master in Biomedicine Study Program, School of Medicine and Health Sciences, Atma Jaya Catholic University of Indonesia, Jakarta 14440, Indonesia.
  • Kristin H; Department of Parasitology, School of Medicine and Health Sciences, Atma Jaya Catholic University of Indonesia, Jakarta 14440, Indonesia.
  • Vasandani SR; Department of Parasitology, School of Medicine and Health Sciences, Atma Jaya Catholic University of Indonesia, Jakarta 14440, Indonesia.
  • Mahendra C; Nalagenetics Pte Ltd., Singapore 169204, Singapore.
  • Ali S; Nalagenetics Pte Ltd., Singapore 169204, Singapore.
Diagnostics (Basel) ; 12(12)2022 Dec 14.
Article em En | MEDLINE | ID: mdl-36553167
ABSTRACT
The testing capacity of the laboratory is paramount for better control of the pandemic caused by SARS-CoV-2. The pooling method is promising to increase testing capacity, and the use of direct NAAT-based detection of SARS-CoV-2 on a non-invasive specimen such as saliva will ultimately accelerate the testing capacity. This study aims to validate the pooling-of-four method to quadruple the testing capacity using RNA-extraction-free saliva specimens. In addition, we intend to investigate the preferable stage of pooling, including pre- or post-heating. The compatibility of this approach was also tested on five commercial kits. Saliva specimens stored at -80 °C for several months were proven viable and were used for various tests in this study. Our findings revealed that pooling-of-four specimens had an overall agreement rate of 98.18% with their individual testing. Moreover, we proved that the pooling procedure could be conducted either pre- or post-heating, with no discordance and no significant difference in Ct values generated. When compared to other commercial detection kits, it demonstrated an overall agreement greater than 85%, which exhibits broad compatibility and ensures easy adaptability in clinical settings. This method has been proven reliable and increases the testing capacity up to fourfold.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article