Your browser doesn't support javascript.
loading
Implantable Loop Recorder with Long Sensing Vector: Safety, Acceptability, and Sensing Performance in Pediatric Patients.
Ciriello, Giovanni Domenico; Grimaldi, Nicola; Papaccioli, Giovanni; Correra, Anna; Colonna, Diego; Romeo, Emanuele; Borrelli, Nunzia; De Marco, Marina; Esposito, Raffaella; Russo, Vincenzo; Russo, Maria Giovanna; Sarubbi, Berardo.
Afiliação
  • Ciriello GD; Adult Congenital Heart Disease Unit, Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy. gdciriello@gmail.com.
  • Grimaldi N; Pediatric Cardiology Unit, Monaldi Hospital, "L.Vanvitelli" University, Naples, Italy. gdciriello@gmail.com.
  • Papaccioli G; Adult Congenital Heart Disease Unit, Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy.
  • Correra A; Adult Congenital Heart Disease Unit, Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy.
  • Colonna D; Adult Congenital Heart Disease Unit, Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy.
  • Romeo E; Adult Congenital Heart Disease Unit, Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy.
  • Borrelli N; Adult Congenital Heart Disease Unit, Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy.
  • De Marco M; Adult Congenital Heart Disease Unit, Monaldi Hospital, Via Leonardo Bianchi, 80131, Naples, Italy.
  • Esposito R; Pediatric Cardiology Unit, Monaldi Hospital, "L.Vanvitelli" University, Naples, Italy.
  • Russo V; Pediatric Cardiology Unit, Monaldi Hospital, "L.Vanvitelli" University, Naples, Italy.
  • Russo MG; Cardiology Unit, Monaldi Hospital, "L.Vanvitelli" University, Naples, Italy.
  • Sarubbi B; Pediatric Cardiology Unit, Monaldi Hospital, "L.Vanvitelli" University, Naples, Italy.
Pediatr Cardiol ; 44(5): 1068-1075, 2023 Jun.
Article em En | MEDLINE | ID: mdl-36576525
ABSTRACT
Implantable loop recorders (ILRs) are effective tools for detecting arrhythmias by long-term continuous heart rhythm monitoring. Benefits have been demonstrated even in pediatric patients. ILR with a long sensing vector has recently been designed to improve signal quality in terms of P wave visibility and R wave amplitude. However, there are no data on its use in pediatric patients. We considered a series of pediatric patients implanted with a long sensing vector ILR. Sensing performance, including R wave amplitude and P wave visibility, device-related complications, and diagnostic yield were collected. During follow-up, each patient guided by his/her parents/guardians was also asked to complete a brief questionnaire to assess patient acceptability of the device. Twenty-five consecutive pediatric patients (mean age 11.3 ± 3.5 years, 72% male) were enrolled. The insertion success rate was 100% on the first attempt with no complications. The median amplitude of the R wave was 1.15 mV (interquartile range, 1.01-1.42) with no significant differences between patients aged ≤ or > 10 years (p = 0.726) and between female and male (p = 0.483). P wave was classified as 'always visible' in 24/25 patients (96%). ILR was generally well accepted and tolerated by all involved patients. During a median follow-up of 297 days (117-317), we achieved in 5 patients a correlation between symptoms and rhythm disorders (20%) and ruled out significant arrhythmias in 6 symptomatic children (24%). Long sensing vector ILR showed to be well accepted, with good signal quality and an excellent safety profile even in pediatric patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Eletrocardiografia Ambulatorial Tipo de estudo: Qualitative_research Limite: Adolescent / Child / Female / Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Eletrocardiografia Ambulatorial Tipo de estudo: Qualitative_research Limite: Adolescent / Child / Female / Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article