Your browser doesn't support javascript.
loading
Development of Kovacs model for electrical conductivity of carbon nanofiber-polymer systems.
Arjmandi, Sajad Khalil; Khademzadeh Yeganeh, Jafar; Zare, Yasser; Rhee, Kyong Yop.
Afiliação
  • Arjmandi SK; Department of Polymer Engineering, Faculty of Engineering, Qom University of Technology, P.O. Box: 37195-1519, Qom, Iran.
  • Khademzadeh Yeganeh J; Department of Polymer Engineering, Faculty of Engineering, Qom University of Technology, P.O. Box: 37195-1519, Qom, Iran.
  • Zare Y; Biomaterials and Tissue Engineering Research Group, Department of Interdisciplinary Technologies, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, Tehran, Iran. y.zare@aut.ac.ir.
  • Rhee KY; Department of Mechanical Engineering (BK21 Four), College of Engineering, Kyung Hee University, Yongin, Republic of Korea. rheeky@khu.ac.kr.
Sci Rep ; 13(1): 7, 2023 Jan 02.
Article em En | MEDLINE | ID: mdl-36593230
ABSTRACT
This study develops a model for electrical conductivity of polymer carbon nanofiber (CNF) nanocomposites (PCNFs), which includes two steps. In the first step, Kovacs model is developed to consider the CNF, interphase and tunneling regions as dissimilar zones in the system. In the second step, simple equations are expressed to estimate the resistances of interphase and tunnels, the volume fraction of CNF and percolation onset. Although some earlier models were proposed to predict the electrical conductivity of PCNFs, developing of Kovacs model causes a better understanding of the effects of main factors on the nanocomposite conductivity. The developed model is supported by logical influences of all factors on the conductivity and by experimented conductivity of several samples. The calculations show good accordance to the experimented data and all factors rationally manage the conductivity of PCNFs. The highest conductivity of PCNF is gained as 0.019 S/m at the lowest ranges of polymer tunnel resistivity (ρ = 500 Ω m) and tunneling distance (d = 2 nm), whereas the highest levels of these factors (ρ > 3000 Ω m and d > 6 nm) cannot cause a conductive sample. Also, high CNF volume fraction, poor waviness, long and thin CNF, low "k", thick interphase, high CNF conduction, high percentage of percolated CNFs, low percolation onset and high interphase conductivity cause an outstanding conductivity in PCNF.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article