Your browser doesn't support javascript.
loading
Biomechanical Comparison of WE43-Based Magnesium vs. Titanium Miniplates in a Mandible Fracture Model in Sheep.
Fischer, Heilwig; Schmidt-Bleek, Oskar; Orassi, Vincenzo; Wulsten, Dag; Schmidt-Bleek, Katharina; Heiland, Max; Steffen, Claudius; Rendenbach, Carsten.
Afiliação
  • Fischer H; Department of Oral and Maxillofacial Surgery, Charité-Universitätsmedizin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353 Berlin, Germany.
  • Schmidt-Bleek O; Center for Musculoskeletal Surgery, Charité-Universitätsmedizin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353 Berlin, Germany.
  • Orassi V; Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353 Berlin, Germany.
  • Wulsten D; Department of Oral and Maxillofacial Surgery, Charité-Universitätsmedizin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353 Berlin, Germany.
  • Schmidt-Bleek K; Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353 Berlin, Germany.
  • Heiland M; Department of Oral and Maxillofacial Surgery, Charité-Universitätsmedizin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Augustenburger Platz 1, 13353 Berlin, Germany.
  • Steffen C; Berlin-Brandenburg School for Regenerative Therapies, Augustenburger Platz 1, 13353 Berlin, Germany.
  • Rendenbach C; Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Julius Wolff Institute, Augustenburger Platz 1, 13353 Berlin, Germany.
Materials (Basel) ; 16(1)2022 Dec 22.
Article em En | MEDLINE | ID: mdl-36614440
In fractures of the mandible, osteosynthesis with titanium plates is considered the gold standard. Titanium is an established and reliable material, its main disadvantages being metal artefacts and the need for removal in case of osteosynthesis complications. Magnesium, as a resorbable material with an elastic modulus close to cortical bone, offers a resorbable alternative osteosynthesis material, yet mechanical studies in mandible fracture fixation are still missing. The hypothesis of this study was that magnesium miniplates show no significant difference in the mechanical integrity provided for fracture fixation in mandible fractures under load-sharing indications. In a non-inferiority test, a continuous load was applied to a sheep mandible fracture model with osteosynthesis using either titanium miniplates of 1.0 mm thickness (Ti1.0), magnesium plates of 1.75 mm (Mg1.75), or magnesium plates of 1.5 mm thickness (Mg1.5). No significant difference (p > 0.05) was found in the peak force at failure, stiffness, or force at vertical displacement of 1.0 mm between Mg1.75, Mg1.5, and Ti1.0. This study shows the non-inferiority of WE43 magnesium miniplates compared to the clinical gold standard titanium miniplates.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article