Your browser doesn't support javascript.
loading
Utilisation of 3D Printing in the Manufacturing of an Anthropomorphic Paediatric Head Phantom for the Optimisation of Scanning Parameters in CT.
Jusufbegovic, Merim; Pandzic, Adi; Busuladzic, Mustafa; Civa, Lejla M; Gazibegovic-Busuladzic, Azra; Sehic, Adnan; Vegar-Zubovic, Sandra; Jasic, Rahima; Beganovic, Adnan.
Afiliação
  • Jusufbegovic M; Radiology Clinic, Sarajevo University Clinical Center, 71000 Sarajevo, Bosnia and Herzegovina.
  • Pandzic A; Department of Radiological Technologies, Faculty of Health Studies, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Busuladzic M; Department of Mechanical Production Engineering, Faculty of Mechanical Engineering Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Civa LM; Faculty of Medicine, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Gazibegovic-Busuladzic A; Sarajevo Medical School, University Sarajevo School of Science and Technology, 71210 Ilidza, Bosnia and Herzegovina.
  • Sehic A; Faculty of Science, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Vegar-Zubovic S; Department of Radiological Technologies, Faculty of Health Studies, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
  • Jasic R; Radiology Clinic, Sarajevo University Clinical Center, 71000 Sarajevo, Bosnia and Herzegovina.
  • Beganovic A; Faculty of Medicine, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
Diagnostics (Basel) ; 13(2)2023 Jan 16.
Article em En | MEDLINE | ID: mdl-36673137
ABSTRACT
Computed tomography (CT) is a diagnostic imaging process that uses ionising radiation to obtain information about the interior anatomic structure of the human body. Considering that the medical use of ionising radiation implies exposing patients to radiation that may lead to unwanted stochastic effects and that those effects are less probable at lower doses, optimising imaging protocols is of great importance. In this paper, we used an assembled 3D-printed infant head phantom and matched its image quality parameters with those obtained for a commercially available adult head phantom using the imaging protocol dedicated for adult patients. In accordance with the results, an optimised scanning protocol was designed which resulted in dose reductions for paediatric patients while keeping image quality at an adequate level.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Ano de publicação: 2023 Tipo de documento: Article