Your browser doesn't support javascript.
loading
In Vivo Biofilm Formation on Novel PEEK, Titanium, and Zirconia Implant Abutment Materials.
Wiessner, Andreas; Wassmann, Torsten; Wiessner, Johanna Maria; Schubert, Andrea; Wiechens, Bernhard; Hampe, Tristan; Bürgers, Ralf.
Afiliação
  • Wiessner A; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany.
  • Wassmann T; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany.
  • Wiessner JM; Department of Orthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany.
  • Schubert A; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany.
  • Wiechens B; Department of Orthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany.
  • Hampe T; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany.
  • Bürgers R; Department of Prosthodontics, University Medical Center Göttingen, 37075 Göttingen, Germany.
Int J Mol Sci ; 24(2)2023 Jan 16.
Article em En | MEDLINE | ID: mdl-36675292
ABSTRACT
The formation of biofilms on the surface of dental implants and abutment materials may lead to peri-implantitis and subsequent implant failure. Recently, innovative materials such as polyether-ether-ketone (PEEK) and its modifications have been used as abutment materials. However, there is limited knowledge on microbial adhesion to PEEK materials. The aim of this in vivo study was to investigate biofilm formation on the surface of conventional (titanium and zirconia) and PEEK implant abutment materials. Split specimens of titanium, zirconia, PEEK, and modified PEEK (PEEK-BioHPP) were manufactured, mounted in individual removable acrylic upper jaw splints, and worn by 20 healthy volunteers for 24 h. The surface roughness was determined using widefield confocal microscopy. Biofilm accumulation was investigated by fluorescence microscopy and quantified by imaging software. The surface roughness of the investigated materials was <0.2 µm and showed no significant differences between the materials. Zirconia showed the lowest biofilm formation, followed by titanium, PEEK, and PEEK-BioHPP. Differences were significant (p < 0.001) between the investigated materials, except for the polyether-ether-ketones. Generally, biofilm formation was significantly higher (p < 0.05) in the posterior region of the oral cavity than in the anterior region. The results of the present study show a material-dependent susceptibility to biofilm formation. The risk of developing peri-implantitis may be reduced by a specific choice of abutment material.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Peri-Implantite Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Peri-Implantite Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article