Your browser doesn't support javascript.
loading
Short-Term Stability of Electrochemical Properties of Layer-by-Layer Coated Heterogeneous Ion Exchange Membranes.
Sarapulova, Veronika; Nevakshenova, Ekaterina; Tsygurina, Kseniia; Ruleva, Valentina; Kirichenko, Anna; Kirichenko, Ksenia.
Afiliação
  • Sarapulova V; Physical Chemistry Department, Kuban State University, 149 Stavropolskaya st., 350040 Krasnodar, Russia.
  • Nevakshenova E; Physical Chemistry Department, Kuban State University, 149 Stavropolskaya st., 350040 Krasnodar, Russia.
  • Tsygurina K; Physical Chemistry Department, Kuban State University, 149 Stavropolskaya st., 350040 Krasnodar, Russia.
  • Ruleva V; Physical Chemistry Department, Kuban State University, 149 Stavropolskaya st., 350040 Krasnodar, Russia.
  • Kirichenko A; Department of Electric Engineering Thermotechnics and Renewable Energy Sources, Kuban State Agrarian University Named after I.T. Trubilin, 13 Kalinina st., 350004 Krasnodar, Russia.
  • Kirichenko K; Physical Chemistry Department, Kuban State University, 149 Stavropolskaya st., 350040 Krasnodar, Russia.
Membranes (Basel) ; 13(1)2022 Dec 29.
Article em En | MEDLINE | ID: mdl-36676852
ABSTRACT
Layer-by-layer adsorption allows the creation of versatile functional coatings for ion exchange membranes, but the stability of the coating and resulting properties of modified membranes in their operation is a frequently asked question. This paper examines the changes in voltammetric curves of layer-by-layer coated cation exchange membranes and pH-metry of desalination chamber with a studied membrane and an auxiliary anion exchange membrane after short-term tests, including over-limiting current modes. The practical operation of the membranes did not affect the voltammetric curves, but enhanced the generation of H+ and OH- ions in a system with polyethylenimine modified membrane in Ca2+ containing solution. It is shown that a distinction between the voltammetric curves of the membranes modified and the different polyamines persists during the operation and that, in the case of polyethylenimine, there is an additional zone of growth of potential drop in voltammetric curves and stronger generation of H+ and OH- ions as indicated by pH-metry.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article