Your browser doesn't support javascript.
loading
Comparison of bone marrow biopsy and fluorodeoxyglucose-positron emission tomography for the assessment of bone marrow infiltration in children with Hodgkin's lymphoma.
Arslantas, Esra; Ayçiçek, Ali; Akici, Ferhan; Özkara, Selvinaz; Yilmaz, Burçak; Özdemir, Nihal; Bayram, Cengiz.
Afiliação
  • Arslantas E; pediatric hematology oncology, Basaksehir Çam ve Sakura Sehir Hastanesi, Istanbul, Turkey.
  • Ayçiçek A; pediatric hematology oncology, Basaksehir Çam ve Sakura Sehir Hastanesi, Istanbul, Turkey.
  • Akici F; pediatric hematology oncology, Istanbul Kanuni Sultan Süleyman Egitim ve Arastirma Hastanesi, Istanbul, Turkey.
  • Özkara S; Pathology, Basaksehir Çam ve Sakura Sehir Hastanesi, Istanbul, Turkey.
  • Yilmaz B; Nuclear Medicine, Basaksehir Çam ve Sakura Sehir Hastanesi, Istanbul, Turkey.
  • Özdemir N; pediatric hematology oncology, Istinye Universitesi, Istanbul, Turkey.
  • Bayram C; pediatric hematology oncology, Basaksehir Çam ve Sakura Sehir Hastanesi, Istanbul, Turkey.
Nuklearmedizin ; 62(1): 20-26, 2023 Feb.
Article em En | MEDLINE | ID: mdl-36746148
ABSTRACT

PURPOSE:

To compare bone marrow biopsy (BMB) with [18F]-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (PET/CT) imaging in the demonstration of bone marrow involvement in children with Hodgkin's Lymphoma (HL) and to investigate the effectiveness of PET/CT imaging and thus the necessity for BMB at staging.

METHODS:

Pediatric patients with HL, who underwent both bilateral iliac BMB and PET/CT imaging at disease staging were retrospectively analyzed. In determining bone marrow involvement (BMinv), BMB and/or first/follow-up PET/CT imaging were eligible for review.

RESULTS:

Fifty-six patients were included. BMinv was detected by PET/CT imaging in 6/56 (10.7%), whereas the proportion was 3/56 (5.3%) in BMB specimens. Bone marrow biopsies and PET/CT images were concordant in 53/56 (94.6%) patients with BMB specimens missing three cases of BMinv detected by PET/CT. When diagnostic accuracy was calculated, sensitivity, specificity, positive predictive value and negative predictive values for PET/CT were 100%, 100%, 100%, 100%, respectively, and the same values for BMB were 50%, 100%, 100%, 94.3%, respectively.

CONCLUSIONS:

The results of PET/CT and BMB for staging of pediatric HL patients were compatible, and PET/CT imaging was found to provide high diagnostic performance in determining BMinv. In keeping with earlier research, the current study showed that BMB may not be necessary in every patient at staging, and should be reserved for cases where PET/CT is inconclusive.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Medula Óssea / Doença de Hodgkin Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Child / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Medula Óssea / Doença de Hodgkin Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Child / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article