Your browser doesn't support javascript.
loading
The effect of a convergent transmucosal neck on soft tissues and radiographic outcomes: a 1-year follow-up randomized controlled trial.
Morón-Conejo, Belén; Sanz-Sánchez, Ignacio; Salido, Maria Paz; Martínez-Rus, Francisco; Pradíes, Guillermo.
Afiliação
  • Morón-Conejo B; Analysis of Techniques, Material and Instruments Applied to Digital Dentistry and CAD/CAM Procedures Research Group, University Complutense, Madrid, Spain.
  • Sanz-Sánchez I; ETEP (Etiology and Therapy of Periodontal and Peri-Implant Diseases) Research Group, University Complutense, Madrid, Spain.
  • Salido MP; Analysis of Techniques, Material and Instruments Applied to Digital Dentistry and CAD/CAM Procedures Research Group, University Complutense, Madrid, Spain. mpsalido@ucm.es.
  • Martínez-Rus F; Department of Conservative and Prosthetic Dentistry, Faculty of Dentistry, University Complutense of Madrid, Plaza Ramón Y Cajal S/N. 28040, Madrid, Spain. mpsalido@ucm.es.
  • Pradíes G; Analysis of Techniques, Material and Instruments Applied to Digital Dentistry and CAD/CAM Procedures Research Group, University Complutense, Madrid, Spain.
Clin Oral Investig ; 27(6): 2923-2933, 2023 Jun.
Article em En | MEDLINE | ID: mdl-36749412
ABSTRACT

PURPOSE:

The aim of this randomized controlled clinical trial was to evaluate peri-implant marginal bone levels (MBLs) and soft tissue dimension changes 1 year after loading. Patients in the control group received bone-level implants, whereas in the test group, tissue-level implants with a convergent transmucosal neck were used. MATERIAL AND

METHODS:

MBLs were calculated by measuring the distance from the implant shoulder to the first visible bone-to-implant contact using standardized periapical digital radiographs. Baseline (day of loading) and follow-up digital models obtained with an intraoral scanner were used to quantify the changes in the peri-implant soft tissue dimensions with a best-fit algorithm.

RESULTS:

The difference between final and baseline MBLs showed a mean bone loss of 0.16 ± 0.01 mm in the test group (n = 15) and 0.45 ± 0.09 mm in the control group (n = 14) (p > 0.05). Soft tissue contour at the level of the gingival margin (GM) increased by 1.96 ± 2.69 mm in the test group and 0.65 ± 0.42 mm in the control group (p = 0.167). Both groups showed a coronal displacement of the gingival margin with no significant differences among them.

CONCLUSIONS:

The present study demonstrated peri-implant hard and soft tissues stability at both implant designs with no significant differences 12 months after loading. CLINICAL RELEVANCE There is still insufficient scientific evidence to demonstrate the role and advantages of the convergent transmucosal neck on the behavior of the peri-implant soft and hard tissues stability compared to a straight neck in bone-level implants 12 months after loading.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Perda do Osso Alveolar / Carga Imediata em Implante Dentário Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Perda do Osso Alveolar / Carga Imediata em Implante Dentário Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article