Your browser doesn't support javascript.
loading
Reproducibility of 2D versus 3D radiomics for quantitative assessment of fetal lung development: a retrospective fetal MRI study.
Watzenboeck, Martin L; Heidinger, Benedikt H; Rainer, Julian; Schmidbauer, Victor; Ulm, Barbara; Rubesova, Erika; Prayer, Daniela; Kasprian, Gregor; Prayer, Florian.
Afiliação
  • Watzenboeck ML; Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Heidinger BH; Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Rainer J; Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Schmidbauer V; Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Ulm B; Department of Obstetrics and Gynecology, Medical University of Vienna, Spitalgasse 23, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Rubesova E; Department of Pediatric Radiology, Lucile Packard Children's Hospital at Stanford, Stanford University, 725 Welch Road, Stanford, CA, 94305, USA.
  • Prayer D; Imaging Bellaria, Bellariastrasse 3, 1010, Vienna, Austria.
  • Kasprian G; Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
  • Prayer F; Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria. florian.prayer@meduniwien.ac.at.
Insights Imaging ; 14(1): 31, 2023 Feb 08.
Article em En | MEDLINE | ID: mdl-36752863
ABSTRACT

PURPOSE:

To investigate the reproducibility of radiomics features extracted from two-dimensional regions of interest (2D ROIs) versus whole lung (3D) ROIs in repeated in-vivo fetal magnetic resonance imaging (MRI) acquisitions.

METHODS:

Thirty fetal MRI scans including two axial T2-weighted acquisitions of the lungs were analysed. 2D (lung at the level of the carina) and 3D (whole lung) ROIs were manually segmented using ITK-Snap. Ninety-five radiomics features were extracted from 2 and 3D ROIs in initial and repeat acquisitions using Pyradiomics. Radiomics feature intra-class correlation coefficients (ICC) were calculated between 2 and 3D ROIs in the initial acquisition, and between 2 and 3D ROIs in repeated acquisitions, respectively.

RESULTS:

MRI data of 11 (36.7%) female and 19 (63.3%) male fetuses acquired at a median 25 + 0 gestational weeks plus days (GW) (interquartile range [IQR] 23 + 4 - 27 + 0 GW) were assessed. Median radiomics feature ICC between 2 and 3D ROIs in the initial MRI acquisition was 0.733 (IQR 0.313-0.814, range 0.018-0.970). ICCs between radiomics features extracted using 3D ROIs in initial and repeat acquisitions (median 0.908 [IQR 0.824-0.929, range 0.335-0.996]) were significantly higher compared to 2D ROIs (0.771 [0.699-0.835, 0.048-0.965]) (p < 0.001).

CONCLUSION:

Fetal MRI radiomics features extracted from 3D whole lung segmentation masks showed significantly higher reproducibility across repeat acquisitions compared to 2D ROIs. Therefore, fetal MRI whole lung radiomics features are robust diagnostic and potentially prognostic tools in the image-based in-vivo quantitative assessment of lung development.