Your browser doesn't support javascript.
loading
Metal-on-Metal Hips: Ten-Year Clinical and Radiographic Outcomes of the ADEPT Metal-on-Metal Hip Resurfacing and Modular Total Hip Arthroplasty.
Mancino, Fabio; Finsterwald, Michael A; Jones, Christopher W; Prosser, Gareth H; Yates, Piers J.
Afiliação
  • Mancino F; Department of Orthopaedics, The Orthopaedic Research Foundation of Western Australia (ORFWA), Fiona Stanley Hospital, 6150 Perth, Australia.
  • Finsterwald MA; Department of Orthopaedics, The Orthopaedic Research Foundation of Western Australia (ORFWA), Fiona Stanley Hospital, 6150 Perth, Australia.
  • Jones CW; Department of Orthopaedics, The Orthopaedic Research Foundation of Western Australia (ORFWA), Fiona Stanley Hospital, 6150 Perth, Australia.
  • Prosser GH; Curtin Medical School, Faculty of Health Sciences, Curtin University, 6102 Perth, Australia.
  • Yates PJ; Department of Orthopaedics, The Orthopaedic Research Foundation of Western Australia (ORFWA), Fiona Stanley Hospital, 6150 Perth, Australia.
J Clin Med ; 12(3)2023 Jan 22.
Article em En | MEDLINE | ID: mdl-36769537
ABSTRACT

BACKGROUND:

The aim of this study is to update the 10-year follow-up survivorship and metal ions levels of a cohort of metal-on-metal (MoM) hip resurfacing (HR) and large-diameter-head (LDH) total hip arthroplasty (THA).

METHODS:

The study is a retrospective analysis of prospectively collected data that compared the outcomes of 24 MoM HR (21 patients) and 15 (11 patients) modular LHD MoM THA at >10 years follow-up. Baseline characteristics as well as intraoperative and postoperative information were collected, including complications, revisions, clinical and radiographic outcomes, and serum metal ions level (Cobalt, Chromium). Metal ion levels were compared using a two-tailed unpaired t-test and Wilcoxon signed-rank test (jamovi v2.3.3.0, Sydney, NSW, AU).

RESULTS:

No significant differences were detected in gender, BMI, and ASA score between the two groups. Patients in the modular THA group were significantly older (57 years vs. 46 years; p < 0.05). The HR overall survivorship was 91.7% (22 of 24 hips) with survivorship from implant failure and/or aseptic loosening and/or metal debris related 100% of problems. The modular THA overall survivorship was 86.7% (13 of 15 hips) with survivorship from implant aseptic loosening and metal ions complications of 93.4% (14 of 15 hips). No significant difference was noted when comparing clinical outcomes. Metal ions were significantly lower in the HR group (Co 25.8 nmol/L vs. 89 nmol/L; p < 0.001-Cr 33.5 nmol/L vs. 55.2 nmol/L; p = 0.026).

CONCLUSION:

Both implants reported excellent and comparable clinical outcomes at >10 years follow-up. The Adept HR reported remarkable survivorship, in line with the registry data, proving once again its reliability in young active males. The modular LDH THA, despite being discontinued, presented higher reliability and a lower failure rate when compared with similar withdrawn MoM implants. Trunnionosis did not appear to be a significant problem in this particular modular design.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article