Your browser doesn't support javascript.
loading
Clinical Trial for the Safety and Feasibility of Pedicle Screws Coated with a Fibroblast Growth Factor-2-Apatite Composite Layer for Posterior Cervical Fusion Surgery.
Nagashima, Katsuya; Hara, Yuki; Mutsuzaki, Hirotaka; Totoki, Yasukazu; Okano, Eriko; Mataki, Kentaro; Matsumoto, Yukei; Yanagisawa, Yohei; Noguchi, Hiroshi; Sogo, Yu; Ito, Atsuo; Koda, Masao; Yamazaki, Masashi.
Afiliação
  • Nagashima K; Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8575, Japan.
  • Hara Y; Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8575, Japan.
  • Mutsuzaki H; Department of Orthopedic Surgery, Ibaraki Prefectural University of Health Sciences, Ami 300-0394, Japan.
  • Totoki Y; Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8575, Japan.
  • Okano E; Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8575, Japan.
  • Mataki K; Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8575, Japan.
  • Matsumoto Y; Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8575, Japan.
  • Yanagisawa Y; Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8575, Japan.
  • Noguchi H; Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8575, Japan.
  • Sogo Y; Technology Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba 305-8560, Japan.
  • Ito A; Technology Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba 305-8560, Japan.
  • Koda M; Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8575, Japan.
  • Yamazaki M; Department of Orthopedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba 305-8575, Japan.
J Clin Med ; 12(3)2023 Jan 26.
Article em En | MEDLINE | ID: mdl-36769595
ABSTRACT
To solve the instrument loosening problem, we developed a fibroblast growth factor-2-calcium phosphate composite layer as a novel coating material to improve screw fixation strength. The primary aim of the present study was to demonstrate the safety and feasibility of screws coated with the FGF-2-calcium phosphate composite layer for posterior instrumented surgery of the cervical spine. The trial design was a single-arm, open-label, safety and feasibility study. Patients receiving fusion of the cervical spine from C2 (or C3) to C7 (or T1) were recruited. The primary endpoint to confirm safety was any screw-related adverse events. Seven patients who underwent posterior fusion surgery of the cervical spine were enrolled in the present study. The coated pedicle screws were inserted bilaterally into the lowest instrumented vertebrae. There was only one severe adverse event unrelated with the coated screw. Three out of the fourteen coated screws showed loosening. The present results prove the safety and feasibility of pedicle screws coated with the FGF-2-calcium phosphate composite layer for fusion surgery in the cervical spine. This is the first step to apply this novel surface coating in the field of spine surgery.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article