Aligned Polyhydroxyalkanoate Blend Electrospun Fibers as Intraluminal Guidance Scaffolds for Peripheral Nerve Repair.
Taylor, Caroline S; Behbehani, Mehri; Glen, Adam; Basnett, Pooja; Gregory, David A; Lukasiewicz, Barbara B; Nigmatullin, Rinat; Claeyssens, Frederik; Roy, Ipsita; Haycock, John W.
Afiliação
  • Taylor CS; Department of Materials Science & and Engineering, The University of Sheffield, Sheffield S3 7HQ, United Kingdom.
  • Behbehani M; The Electrospinning Company, Unit 5, Zephyr Building, Eighth St., Harwell Campus, Harwell, Didcot OX11 0RL, United Kingdom.
  • Glen A; Department of Materials Science & and Engineering, The University of Sheffield, Sheffield S3 7HQ, United Kingdom.
  • Basnett P; School of Life Sciences, College of Liberal Arts and Sciences, University of Westminster, London W1B 2HW, United Kingdom.
  • Gregory DA; Department of Materials Science & and Engineering, The University of Sheffield, Sheffield S3 7HQ, United Kingdom.
  • Lukasiewicz BB; School of Life Sciences, College of Liberal Arts and Sciences, University of Westminster, London W1B 2HW, United Kingdom.
  • Nigmatullin R; School of Life Sciences, College of Liberal Arts and Sciences, University of Westminster, London W1B 2HW, United Kingdom.
  • Claeyssens F; Department of Materials Science & and Engineering, The University of Sheffield, Sheffield S3 7HQ, United Kingdom.
  • Roy I; Department of Materials Science & and Engineering, The University of Sheffield, Sheffield S3 7HQ, United Kingdom.
  • Haycock JW; Department of Materials Science & and Engineering, The University of Sheffield, Sheffield S3 7HQ, United Kingdom.
ACS Biomater Sci Eng ; 9(3): 1472-1485, 2023 03 13.
Article em En | MEDLINE | ID: mdl-36848250
ABSTRACT
The use of nerve guidance conduits (NGCs) to treat peripheral nerve injuries is a favorable approach to the current "gold standard" of autografting. However, as simple hollow tubes, they lack specific topographical and mechanical guidance cues present in nerve grafts and therefore are not suitable for treating large gap injuries (30-50 mm). The incorporation of intraluminal guidance scaffolds, such as aligned fibers, has been shown to increase neuronal cell neurite outgrowth and Schwann cell migration distances. A novel blend of PHAs, P(3HO)/P(3HB) (5050), was investigated for its potential as an intraluminal aligned fiber guidance scaffold. Aligned fibers of 5 and 8 µm diameter were manufactured by electrospinning and characterized using SEM. Fibers were investigated for their effect on neuronal cell differentiation, Schwann cell phenotype, and cell viability in vitro. Overall, P(3HO)/P(3HB) (5050) fibers supported higher neuronal and Schwann cell adhesion compared to PCL fibers. The 5 µm PHA blend fibers also supported significantly higher DRG neurite outgrowth and Schwann cell migration distance using a 3D ex vivo nerve injury model.