Your browser doesn't support javascript.
loading
Photoplethysmography Signal Wavelet Enhancement and Novel Features Selection for Non-Invasive Cuff-Less Blood Pressure Monitoring.
Attivissimo, Filippo; De Palma, Luisa; Di Nisio, Attilio; Scarpetta, Marco; Lanzolla, Anna Maria Lucia.
Afiliação
  • Attivissimo F; Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.
  • De Palma L; Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.
  • Di Nisio A; Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.
  • Scarpetta M; Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.
  • Lanzolla AML; Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.
Sensors (Basel) ; 23(4)2023 Feb 19.
Article em En | MEDLINE | ID: mdl-36850919
In this paper, new features relevant to blood pressure (BP) estimation using photoplethysmography (PPG) are presented. A total of 195 features, including the proposed ones and those already known in the literature, have been calculated on a set composed of 50,000 pulses from 1080 different patients. Three feature selection methods, namely Correlation-based Feature Selection (CFS), RReliefF and Minimum Redundancy Maximum Relevance (MRMR), have then been applied to identify the most significant features for BP estimation. Some of these features have been extracted through a novel PPG signal enhancement method based on the use of the Maximal Overlap Discrete Wavelet Transform (MODWT). As a matter of fact, the enhanced signal leads to a reliable identification of the characteristic points of the PPG signal (e.g., systolic, diastolic and dicrotic notch points) by simple means, obtaining results comparable with those from purposely defined algorithms. For systolic points, mean and std of errors computed as the difference between the locations obtained using a purposely defined already known algorithm and those using the MODWT enhancement are, respectively, 0.0097 s and 0.0202 s; for diastolic points they are, respectively, 0.0441 s and 0.0486 s; for dicrotic notch points they are 0.0458 s and 0.0896 s. Hence, this study leads to the selection of several new features from the MODWT enhanced signal on every single pulse extracted from PPG signals, in addition to features already known in the literature. These features can be employed to train machine learning (ML) models useful for estimating systolic blood pressure (SBP) and diastolic blood pressure (DBP) in a non-invasive way, which is suitable for telemedicine health-care monitoring.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Fotopletismografia Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Fotopletismografia Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article