Your browser doesn't support javascript.
loading
Liver cirrhosis and tumor location can affect the range of intrahepatic microwave ablation zone.
Ding, Wen-Zhen; Wei, Hao; Wu, Jia-Peng; Cheng, Zhi-Gang; Han, Zhi-Yu; Liu, Fang-Yi; Yu, Jie; Liang, Ping.
Afiliação
  • Ding WZ; Fifth Medical Center of Chinese, PLA General Hospital, Beijing, China.
  • Wei H; School of Biological Science and Medical Engineering, Southeast University, Nanjing, Jiangsu, China.
  • Wu JP; Fifth Medical Center of Chinese, PLA General Hospital, Beijing, China.
  • Cheng ZG; Fifth Medical Center of Chinese, PLA General Hospital, Beijing, China.
  • Han ZY; Fifth Medical Center of Chinese, PLA General Hospital, Beijing, China.
  • Liu FY; Fifth Medical Center of Chinese, PLA General Hospital, Beijing, China.
  • Yu J; Fifth Medical Center of Chinese, PLA General Hospital, Beijing, China.
  • Liang P; Fifth Medical Center of Chinese, PLA General Hospital, Beijing, China.
Int J Hyperthermia ; 40(1): 2181843, 2023.
Article em En | MEDLINE | ID: mdl-36854449
ABSTRACT

BACKGROUND:

The range of an ablation zone (AZ) plays a crucial role in the treatment effect of microwave ablation (MWA). The aim of this study was to analyze the factors influencing the AZ range.

METHODS:

Fourteen factors in four areas were included patient-related factors (sex, age), disease-related factors (tumor location, liver cirrhosis), serological factors (ALT, AST, total protein, albumin, total bilirubin, direct bilirubin, and platelets), and MWA parameters (ablation time, power, and needle type). Multiple sequence MRI was used to delineate AZ by three radiologists using 3D Slicer. MATLAB was used to calculate the AZ length, width, and area of the largest section. Linear regression analysis was used to analyze influencing factors. Moreover, a subgroup analysis was conducted for patients with viral hepatitis.

RESULT:

220 patients with 290 tumors were included between 2010-2021. In addition to MWA parameters, cirrhosis and tumor location were significant factors that influenced AZ (p < 0.001). The standardized coefficient (beta) of cirrhosis (cirrhosis vs. non-cirrhosis) was positive, which meant cirrhosis would lead to a decrease in AZ range. The beta of tumor location (near the hepatic hilar zone, intermediate zone, and periphery zone) was negative, indicating that AZ range decreased as the tumor location approached the hepatic hilum. For viral hepatitis patients, Fibrosis 4 (FIB4) score was a significant factor influencing AZ (p < 0.001), and the beta was negative, indicating that AZ range decreased as FIB4 increased.

CONCLUSION:

Liver cirrhosis, tumor location, and FIB4 affect the AZ range and should be considered when planning MWA parameters.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cirrose Hepática / Micro-Ondas Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cirrose Hepática / Micro-Ondas Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article