The fluorescence and colorimetric dual-readout probe for clinical rapid detection of mycophenolic acid by the poly(ethylenimine)/silica-coated CdTe quantum dots.
Shi, You Quan; Xu, Zhao; Wang, Le; Wang, Kang; Xu, Li; Zheng, Heng.
Afiliação
  • Shi YQ; Department of Pharmacy, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Xu Z; Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Wang L; Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Wang K; Institute of Organ Transplantation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Xu L; Tongji School of Pharmacy, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Zheng H; Department of Pharmacy, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address: 13607150690@163.com.
Anal Biochem ; 668: 115090, 2023 05 01.
Article em En | MEDLINE | ID: mdl-36870552
It is particularly meaningful to therapeutic drug monitoring (TDM) of mycophenolic acid (MPA) for transplant patients to maximize the drug efficacy and minimize the adverse effect. In this study, a novel fluorescence and colorimetric dual-readout probe was put forward to fast and reliable detect MPA. The blue fluorescence of MPA was largely enhanced in the presence of poly (ethylenimine) (PEI), while the red fluorescence of CdTe@SiO2 (silica-coated CdTe quantum dots) provided a reliable reference signal. Hence, combining PEI70,000 and CdTe@SiO2, a fluorescence and colorimetric dual-readout probe could be constructed. For fluorescence measurement of MPA, the linearity was obtained in the MPA concentration range of 0.5-50 µg/mL, with a limit of detection (LOD) of 33 ng/mL. For the visual detection, the fluorescent colorimetric card was established in the MPA concentration from 0.5 to 50 µg/mL corresponding to the fluorescence color from red to violet and then to blue, which could be used for semi-quantification. Furthermore, in the light of the ColorCollect APP by the smartphone, the ratio of blue and red brightness values was linear with the MPA concentration from 1 to 50 µg/mL; thus, quantification of MPA could be realized by APP with the LOD of 83 ng/mL. The developed method was successfully applied to the analysis of MPA in the plasma samples of three patients after oral administration of mycophenolate mofetil, which was the prodrug of MPA. The result was comparable to those obtained by the clinically widely-used enzyme multiplied immunoassay technique. The developed probe was fast, cost-effective and operational convenience, and possessed high potential for TDM of MPA.