Your browser doesn't support javascript.
loading
Total scattering measurements at the Australian Synchrotron Powder Diffraction beamline: capabilities and limitations.
D'Angelo, Anita M; Brand, Helen E A; Mitchell, Valerie D; Hamilton, Jessica L; Oldfield, Daniel; Liu, Amelia C Y; Gu, Qinfen.
Afiliação
  • D'Angelo AM; Australian Synchrotron, Australian Nuclear Science and Technology Organisation (ANSTO), 800 Blackburn Road, Clayton, Victoria 3168, Australia.
  • Brand HEA; Australian Synchrotron, Australian Nuclear Science and Technology Organisation (ANSTO), 800 Blackburn Road, Clayton, Victoria 3168, Australia.
  • Mitchell VD; Australian Synchrotron, Australian Nuclear Science and Technology Organisation (ANSTO), 800 Blackburn Road, Clayton, Victoria 3168, Australia.
  • Hamilton JL; Australian Synchrotron, Australian Nuclear Science and Technology Organisation (ANSTO), 800 Blackburn Road, Clayton, Victoria 3168, Australia.
  • Oldfield D; Australian Nuclear Science and Technology Organisation (ANSTO), New Illawarra Road, Lucas Heights, New South Wales 2234, Australia.
  • Liu ACY; School of Physics and Astronomy, Monash University, Wellington Road, Clayton, Victoria 3800, Australia.
  • Gu Q; Australian Synchrotron, Australian Nuclear Science and Technology Organisation (ANSTO), 800 Blackburn Road, Clayton, Victoria 3168, Australia.
J Synchrotron Radiat ; 30(Pt 2): 327-339, 2023 Mar 01.
Article em En | MEDLINE | ID: mdl-36891846
This study describes the capabilities and limitations of carrying out total scattering experiments on the Powder Diffraction (PD) beamline at the Australian Synchrotron, ANSTO. A maximum instrument momentum transfer of 19 Å-1 can be achieved if the data are collected at 21 keV. The results detail how the pair distribution function (PDF) is affected by Qmax, absorption and counting time duration at the PD beamline, and refined structural parameters exemplify how the PDF is affected by these parameters. There are considerations when performing total scattering experiments at the PD beamline, including (1) samples need to be stable during data collection, (2) highly absorbing samples with a µR > 1 always require dilution and (3) only correlation length differences >0.35 Šmay be resolved. A case study comparing the PDF atom-atom correlation lengths with EXAFS-derived radial distances of Ni and Pt nanocrystals is also presented, which shows good agreement between the two techniques. The results here can be used as a guide for researchers considering total scattering experiments at the PD beamline or similarly setup beamlines.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article