Your browser doesn't support javascript.
loading
A New Generation of OPM for High Dynamic and Large Bandwidth MEG: The 4He OPMs-First Applications in Healthy Volunteers.
Gutteling, Tjerk P; Bonnefond, Mathilde; Clausner, Tommy; Daligault, Sébastien; Romain, Rudy; Mitryukovskiy, Sergey; Fourcault, William; Josselin, Vincent; Le Prado, Matthieu; Palacios-Laloy, Agustin; Labyt, Etienne; Jung, Julien; Schwartz, Denis.
Afiliação
  • Gutteling TP; CERMEP-Imagerie du Vivant, MEG Departement, 69000 Lyon, France.
  • Bonnefond M; CRNL, UMR_S 1028, HCL, Université Lyon 1, 69000 Lyon, France.
  • Clausner T; CRNL, UMR_S 1028, HCL, Université Lyon 1, 69000 Lyon, France.
  • Daligault S; CRNL, UMR_S 1028, HCL, Université Lyon 1, 69000 Lyon, France.
  • Romain R; CERMEP-Imagerie du Vivant, MEG Departement, 69000 Lyon, France.
  • Mitryukovskiy S; MAG4Health, 38000 Grenoble, France.
  • Fourcault W; MAG4Health, 38000 Grenoble, France.
  • Josselin V; CEA LETI, Minatec Campus, Université Grenoble Alpes, 38000 Grenoble, France.
  • Le Prado M; CEA LETI, Minatec Campus, Université Grenoble Alpes, 38000 Grenoble, France.
  • Palacios-Laloy A; MAG4Health, 38000 Grenoble, France.
  • Labyt E; MAG4Health, 38000 Grenoble, France.
  • Jung J; MAG4Health, 38000 Grenoble, France.
  • Schwartz D; CRNL, UMR_S 1028, HCL, Université Lyon 1, 69000 Lyon, France.
Sensors (Basel) ; 23(5)2023 Mar 03.
Article em En | MEDLINE | ID: mdl-36905007
MagnetoEncephaloGraphy (MEG) provides a measure of electrical activity in the brain at a millisecond time scale. From these signals, one can non-invasively derive the dynamics of brain activity. Conventional MEG systems (SQUID-MEG) use very low temperatures to achieve the necessary sensitivity. This leads to severe experimental and economical limitations. A new generation of MEG sensors is emerging: the optically pumped magnetometers (OPM). In OPM, an atomic gas enclosed in a glass cell is traversed by a laser beam whose modulation depends on the local magnetic field. MAG4Health is developing OPMs using Helium gas (4He-OPM). They operate at room temperature with a large dynamic range and a large frequency bandwidth and output natively a 3D vectorial measure of the magnetic field. In this study, five 4He-OPMs were compared to a classical SQUID-MEG system in a group of 18 volunteers to evaluate their experimental performances. Considering that the 4He-OPMs operate at real room temperature and can be placed directly on the head, our assumption was that 4He-OPMs would provide a reliable recording of physiological magnetic brain activity. Indeed, the results showed that the 4He-OPMs showed very similar results to the classical SQUID-MEG system by taking advantage of a shorter distance to the brain, despite having a lower sensitivity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Magnetoencefalografia / Hélio Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Magnetoencefalografia / Hélio Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article