Your browser doesn't support javascript.
loading
Effect of Selenium Nanoparticle Size on IL-6 Detection Sensitivity in a Lateral Flow Device.
Bradley, Zoe; Coleman, Patrick A; Courtney, Melissa A; Fishlock, Sam; McGrath, Joseph; Uniacke-Lowe, Therese; Bhalla, Nikhil; McLaughlin, James A; Hogan, John; Hanrahan, John P; Yan, Ke-Ting; McKee, Philip.
Afiliação
  • Bradley Z; Biopanda Reagents Ltd., Unit 14, Carrowreagh Business Park, Carrowreagh Road, Belfast BT16 1QQ, United Kingdom.
  • Coleman PA; Nanotechnology and Integrated Bioengineering Centre, School of Engineering, University of Ulster, Belfast BT15 1ED, United Kingdom.
  • Courtney MA; Environmental Research Institute, Glantreo Ltd., Cork T23 XE10, Ireland.
  • Fishlock S; Department of Chemistry, College of SEFS, University College Cork, Kane Building, Cork T12 YN60, Ireland.
  • McGrath J; Environmental Research Institute, Glantreo Ltd., Cork T23 XE10, Ireland.
  • Uniacke-Lowe T; Nanotechnology and Integrated Bioengineering Centre, School of Engineering, University of Ulster, Belfast BT15 1ED, United Kingdom.
  • Bhalla N; Environmental Research Institute, Glantreo Ltd., Cork T23 XE10, Ireland.
  • McLaughlin JA; Department of Chemistry, School of Food and Nutritional Sciences, University College Cork, Level 2 Food Science Building, Cork T12 TP07, Ireland.
  • Hogan J; Nanotechnology and Integrated Bioengineering Centre, School of Engineering, University of Ulster, Belfast BT15 1ED, United Kingdom.
  • Hanrahan JP; Healthcare Technology Hub, School of Engineering, University of Ulster, Belfast BT15 1ED, United Kingdom.
  • Yan KT; Nanotechnology and Integrated Bioengineering Centre, School of Engineering, University of Ulster, Belfast BT15 1ED, United Kingdom.
  • McKee P; Environmental Research Institute, Glantreo Ltd., Cork T23 XE10, Ireland.
ACS Omega ; 8(9): 8407-8414, 2023 Mar 07.
Article em En | MEDLINE | ID: mdl-36910974
ABSTRACT
Sepsis is the body's response to an infection. Existing diagnostic testing equipment is not available in primary care settings and requires long waiting times. Lateral flow devices (LFDs) could be employed in point-of-care (POC) settings for sepsis detection; however, they currently lack the required sensitivity. Herein, LFDs are constructed using 150-310 nm sized selenium nanoparticles (SeNPs) and are compared to commercial 40 nm gold nanoparticles (AuNPs) for the detection of the sepsis biomarker interleukin-6 (IL-6). Both 310 and 150 nm SeNPs reported a lower limit of detection (LOD) than 40 nm AuNPs (0.1 ng/mL compared to 1 ng/mL), although at the cost of test line visual intensity. This is to our knowledge the first use of larger SeNPs (>100 nm) in LFDs and the first comparison of the effect of the size of SeNPs on assay sensitivity in this context. The results herein demonstrate that large SeNPs are viable alternatives to existing commercial labels, with the potential for higher sensitivity than standard 40 nm AuNPs.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article