ABSTRACT

OBJECTIVES:

Matsudaito is a unique surgical sealant with a powerful hemostatic effect that works independent of a patient's blood coagulation function. Because of its mechanism, this sealant is expected to be particularly useful in patients with a poor blood coagulation function, such as in cases of acute aortic syndrome requiring emergency surgery. We, therefore, evaluated the hemostatic static effect of the sealant in both emergency and elective surgery of the thoracic aorta.

METHODS:

We used data obtained from post-marketing surveillance of the sealant. Patients who underwent replacement of the thoracic aorta were enrolled. The hemostatic effect was evaluated as effective if a further hemostatic procedure was not performed after applying the sealant.

RESULTS:

From 46 hospitals in Japan, a total of 542 patients (327 elective and 215 emergency cases) were enrolled. Hospital mortality was 4.0% and 11.6% in elective and emergency cases, respectively (p < 0.05). Among the 1039 anastomoses (609 elective and 430 emergency cases), effective hemostasis was confirmed in 436 (71.6%) elective and 259 (60.2%) emergency cases. The data from the clinical trial of the sealant showed a hemostatic rate of 44.4% in elective control cases without the sealant.

CONCLUSION:

Given that the hemostatic rate in emergency surgery with the sealant seemed to be better than that in elective surgery without the sealant (determined from the clinical trial), we concluded that the sealant was effective in both emergency and elective thoracic surgery of the aorta.