Your browser doesn't support javascript.
loading
Overcoming the matrix effect in the element analysis of steel: Laser ablation-spark discharge-optical emission spectroscopy (LA-SD-OES) and Laser-induced breakdown spectroscopy (LIBS).
Grünberger, Stefan; Ehrentraut, Valentin; Eschlböck-Fuchs, Simon; Hofstadler, Josef; Pissenberger, Andreas; Pedarnig, Johannes D.
Afiliação
  • Grünberger S; Institute of Applied Physics, Johannes Kepler University Linz, A-4040, Linz, Austria. Electronic address: stefan.gruenberger@jku.at.
  • Ehrentraut V; Institute of Applied Physics, Johannes Kepler University Linz, A-4040, Linz, Austria.
  • Eschlböck-Fuchs S; voestalpine Stahl GmbH, A-4020, Linz, Austria.
  • Hofstadler J; voestalpine Stahl GmbH, A-4020, Linz, Austria.
  • Pissenberger A; voestalpine Stahl GmbH, A-4020, Linz, Austria.
  • Pedarnig JD; Institute of Applied Physics, Johannes Kepler University Linz, A-4040, Linz, Austria. Electronic address: http://www.jku.at/applphys.
Anal Chim Acta ; 1251: 341005, 2023 Apr 22.
Article em En | MEDLINE | ID: mdl-36925310
ABSTRACT
The optical emission of plasma on industrial steel samples induced by Laser Ablation-Spark Discharge-Optical Emission Spectroscopy (LA-SD-OES) and by Laser-Induced Breakdown Spectroscopy (LIBS) is investigated and correlated to the volume of ablated steel material. The 36 steel samples investigated have an iron content C(Fe) above 94 wt%. The excitation energy in LIBS (laser pulse of 55 mJ) and in LA-SD-OES (laser pulse of 5 mJ and spark discharge of 50 mJ) is the same. In LA-SD-OES, the optical emission of plasma and the size of ablation craters are very similar for all samples and a linear calibration curve for Mn is measured (R2 = 0.99). In LIBS, however, a pronounced dependence of the plasma emission and of the crater volume on the steel matrix is observed and calibration curves show a strong cross-sensitivity to other elements such as Si (matrix effect). The hardness, grain size, and phase of steel samples are analyzed to correlate the matrix effect in LIBS measurements to a physical property of the specimen. The different behavior for LA-SD-OES and LIBS is probably due to different processes of sampling and plasma excitation. From our results we conclude that LA-SD-OES enables for the element analysis of industrial steel largely independent of composition and structure of samples while in LIBS the matrix effect has to be taken into account.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article