Your browser doesn't support javascript.
loading
Gap Balancing Throughout the Arc of Motion With Navigated TKA and a Novel Force-Controlled Distractor: A Review of the First 273 Cases.
Fan, Wen; Angibaud, Laurent D; Jung, Amaury Y; Hamad, Cyril M; Davis, Mark B; Zirgibel, Brian J; Deister, Jake C; Huddleston, James I.
Afiliação
  • Fan W; Exactech, Gainesville, Florida.
  • Angibaud LD; Exactech, Gainesville, Florida.
  • Jung AY; Blue-Ortho, Meylan, France.
  • Hamad CM; Blue-Ortho, Meylan, France.
  • Davis MB; Davis Orthopaedics, Prescott Valley, Arizona.
  • Zirgibel BJ; Tallahassee Orthopedic Clinic, Tallahassee, Florida.
  • Deister JC; Stormont Vail Hospital, Topeka, Kansas.
  • Huddleston JI; Stanford Healthcare, Stanford, California.
J Arthroplasty ; 38(6S): S246-S252, 2023 06.
Article em En | MEDLINE | ID: mdl-36931358
ABSTRACT

BACKGROUND:

This study evaluated the ability to achieve the targeted soft-tissue balance in terms of medio-lateral (ML) laxity and gap values when using a computer-assisted orthopedic surgery (CAOS) system featuring an intra-articular force-controlled distractor and assessed learning curves associated with the adoption of this technology.

METHODS:

The first 273 cases using this technology were reported without exclusions comparing 1) final ML laxity and 2) final average gap to their predefined targets. For both parameters, the signed and unsigned differentials were reported. The linear mixed model was used to evaluate laxity curve differences between surgeons. A cumulative sum control chart (CUSUM) was applied to assess surgeon learning curves regarding surgical time.

RESULTS:

Both the average signed ML laxity and gap differentials were neutral throughout the full arc of motion. Both the average unsigned ML laxity and gap differentials were linear. Signature of ML laxity and gap differential curves tended to be surgeon-specific. The CUSUM analyses of surgical times demonstrated either a short learning curve or the absence of a discernible learning pattern for surgeons.

CONCLUSION:

Data from all users involved with the pilot release of the balancing device were considered to capture variability in familiarity with the technique and learning curve cases were included. A high ability to achieve targeted gap balance throughout the arc of motion using the proposed method was observed.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Osteoartrite do Joelho / Cirurgia Assistida por Computador Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Osteoartrite do Joelho / Cirurgia Assistida por Computador Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article