Your browser doesn't support javascript.
loading
Electrophysiological demonstration of nonselective His-Purkinje system capture with para-Hisian pacing.
de Zuloaga, Claudio; Ferrari, Andrés.
Afiliação
  • de Zuloaga C; Hospital Nacional Profesor Alejandro Posadas, Ecuador 1449 10ª "B" (CABA), Buenos Aires, Argentina. Electronic address: dezuloaga@fibertel.com.ar.
  • Ferrari A; Arrhythmias and Cardiac Pacing Unit, Hospital São Lucas, Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS), Av. Ipiranga, Porto Alegre 6690, RS, Brazil.
J Electrocardiol ; 79: 38-45, 2023.
Article em En | MEDLINE | ID: mdl-36934491
ABSTRACT

BACKGROUND:

The adverse effects of conventional right ventricular (RV) apical pacing prompted the search for more physiological pacing sites, such as selective and nonselective His bundle pacing (HBP), a variant of nonselective HBP (para-Hisian pacing), and mid-septal pacing. However, knowledge of their true benefit on the physiology of ventricular activation, lead stability, and pacing thresholds is limited. METHODS AND

RESULTS:

We included 152 consecutive patients (mean age 61 ± 24, 63% men) in this retrospective study. Of these, 137 patients with different bradyarrhythmias underwent active fixation lead implantation at the RV apex (n = 54), para-Hisian region (n = 66), or mid interventricular septum (n = 17). Fifteen patients with ventricular preexcitation due to an accessory pathway not undergoing pacing were included as controls. A 12­lead ECG was recorded in all patients, and cardiac electrical synchrony was assessed using the Synchromax® cross-correlation cardiac synchrony index (CSI).

RESULTS:

QRS duration was prolonged in all pacing sites from 114 ± 28 to 160 ± 29 (RV apex), from 110 ± 28 to 122 ± 29 (para-Hisian), and from 121 ± 24 to 154 ± 30 (mid interventricular septum). The CSI was significantly improved only in patients undergoing para-Hisian pacing, despite a slight widening of the QRS interval. There was no difference in pacing thresholds and sensed R-wave voltage between pacing sites. Only 1 lead, implanted at the para-Hisian region (1.5%), was dislodged towards the mid septum 48 h after implantation but did not require repositioning.

CONCLUSIONS:

QRS duration was not associated with changes in CSI, meaning that QRS width does not significantly affect electrical synchrony.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrocardiografia / Feixe Acessório Atrioventricular Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrocardiografia / Feixe Acessório Atrioventricular Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2023 Tipo de documento: Article