Your browser doesn't support javascript.
loading
Diagnostic Accuracy of Fecal Immunochemical Test (FIT) in Bleed-positive and Bleed-negative Colorectal Cancer (CRC) Among a Cohort of 5,090 Subjects who Participated in the Colorectal Neoplasia (CRN) Screening in Brazil.
Eskelinen, Maaret; Meklin, Jannica; Guimaraes, Denise Peixoto; Selander, Tuomas; Syrjänen, Kari; Eskelinen, Matti.
Afiliação
  • Eskelinen M; Department of Surgery, Kuopio University Hospital and School of Medicine, University of Eastern Finland, Kuopio, Finland; matti.eskelinen@kuh.fi.
  • Meklin J; Department of Surgery, Kuopio University Hospital and School of Medicine, University of Eastern Finland, Kuopio, Finland.
  • Guimaraes DP; Molecular Oncology Research Center, Barretos Cancer Hospital, Barretos, Brazil.
  • Selander T; Science Service Center, Kuopio University Hospital, Kuopio, Finland.
  • Syrjänen K; Molecular Oncology Research Center, Barretos Cancer Hospital, Barretos, Brazil.
  • Eskelinen M; SMW Consultants, Ltd., Kaarina, Finland.
Anticancer Res ; 43(4): 1569-1580, 2023 Apr.
Article em En | MEDLINE | ID: mdl-36974786
ABSTRACT
BACKGROUND/

AIM:

This study assessed the diagnostic accuracy (DA) of fecal immunochemical test (FIT) ColonView (CV) and guaiac-based fecal occult blood test (HemoccultSENSA) among bleed-positive (history or signs of intestinal bleeding) and bleed-negative participants (no history or signs of intestinal bleeding) (n=5,090) in colorectal neoplasia (CRN) screening in Brazil. PATIENTS AND

METHODS:

The eligible patients for the study (n=506) collected three consecutive stool samples, to be analyzed by both assays (CV, SENSA). Finally, 421/5090 (8.3%) patients returned both samples, which were subjected to final analysis. Receiver operating characteristic (ROC) analysis with different cut-offs was performed to assess the DA.

RESULTS:

The area under curve (AUC) values for i) visually analyzed (VA) CV for bleed-positive CRC, ii) automatically analyzed (AA) CV for bleed-positive CRC, iii) VA CV for bleed-negative CRC, and iv) AA CV for bleed-negative CRC as endpoints were as follows i) AUC=0.864, ii) AUC=0.933, iii) AUC=0.836, and iv) AUC=0.892. In roccomp analysis, the differences in AUC values were between i) and ii) p=0.068; between i) and iii) p=0.497; between i) and iv) p=0.488; between ii) and iii) p=0.0058; between ii) and iv) p=0.229; and between iii) and iv) p=0.138.

CONCLUSION:

This is the first investigation where two modes of CV test, VA, and AA, for bleed-positive and bleed-negative CRC patients were used as the endpoint. The AA reading of the CV test showed higher DA in bleed-positive than in bleed-negative CRC patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Colorretais / Sangue Oculto Tipo de estudo: Diagnostic_studies / Etiology_studies / Risk_factors_studies / Screening_studies Limite: Humans País/Região como assunto: America do sul / Brasil Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Colorretais / Sangue Oculto Tipo de estudo: Diagnostic_studies / Etiology_studies / Risk_factors_studies / Screening_studies Limite: Humans País/Região como assunto: America do sul / Brasil Idioma: En Ano de publicação: 2023 Tipo de documento: Article