Non-invasive measurements of respiration and heart rate across wildlife species using Eulerian Video Magnification of infrared thermal imagery.
Rzucidlo, Caroline L; Curry, Erin; Shero, Michelle R.
Afiliação
  • Rzucidlo CL; MIT-WHOI Joint Program in Oceanography/Applied Ocean Science & Engineering, Woods Hole and Cambridge, MA, USA. crzucidlo@whoi.edu.
  • Curry E; Biology Department, Woods Hole Oceanographic Institution, Woods Hole, MA, USA. crzucidlo@whoi.edu.
  • Shero MR; Center for Conservation and Research of Endangered Wildlife (CREW), Cincinnati Zoo & Botanical Garden, Cincinnati, OH, USA.
BMC Biol ; 21(1): 61, 2023 03 29.
Article em En | MEDLINE | ID: mdl-36978082
ABSTRACT

BACKGROUND:

An animal's metabolic rate, or energetic expenditure, both impacts and is impacted by interactions with its environment. However, techniques for obtaining measurements of metabolic rate are invasive, logistically difficult, and costly. Red-green-blue (RGB) imaging tools have been used in humans and select domestic mammals to accurately measure heart and respiration rate, as proxies of metabolic rate. The purpose of this study was to investigate if infrared thermography (IRT) coupled with Eulerian video magnification (EVM) would extend the applicability of imaging tools towards measuring vital rates in exotic wildlife species with different physical attributes.

RESULTS:

We collected IRT and RGB video of 52 total species (39 mammalian, 7 avian, 6 reptilian) from 36 taxonomic families at zoological institutions and used EVM to amplify subtle changes in temperature associated with blood flow for respiration and heart rate measurements. IRT-derived respiration and heart rates were compared to 'true' measurements determined simultaneously by expansion of the ribcage/nostrils and stethoscope readings, respectively. Sufficient temporal signals were extracted for measures of respiration rate in 36 species (85% success in mammals; 50% success in birds; 100% success in reptiles) and heart rate in 24 species (67% success in mammals; 33% success in birds; 0% success in reptiles) using IRT-EVM. Infrared-derived measurements were obtained with high accuracy (respiration rate, mean absolute error 1.9 breaths per minute, average percent error 4.4%; heart rate, mean absolute error 2.6 beats per minute, average percent error 1.3%). Thick integument and animal movement most significantly hindered successful validation.

CONCLUSION:

The combination of IRT with EVM analysis provides a non-invasive method to assess individual animal health in zoos, with great potential to monitor wildlife metabolic indices in situ.