Your browser doesn't support javascript.
loading
Lower Patient Height and Weight Are Predisposing Factors for Complex Radial Arterial Catheterization.
Huber, Kristine; Menzenbach, Jan; Velten, Markus; Kim, Se-Chan; Hilbert, Tobias.
Afiliação
  • Huber K; Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany.
  • Menzenbach J; Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany.
  • Velten M; Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany.
  • Kim SC; Department of Anesthesiology, Perioperative Care and Pain Medicine, RKH Hospital gGmbH, Kurt-Lindemann-Weg 10, 71706 Markgröningen, Germany.
  • Hilbert T; Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany.
J Clin Med ; 12(6)2023 Mar 13.
Article em En | MEDLINE | ID: mdl-36983225
ABSTRACT

Background:

Radial artery (RA) catheterization for invasive blood pressure monitoring is often performed via palpation, and an ultrasound is used secondarily only in case of multiple unsuccessful attempts. Although more elaborate, it has been shown that primary ultrasound-guided catheterization may be advantageous compared with palpation. The aim of this study was to identify factors associated with difficult RA catheterization.

Methods:

Left RA ultrasound assessments were performed in patients with indicated invasive blood pressure monitoring the day before surgery. RA catheterization was performed by personnel blinded to the ultrasound results. Based on the number of attempts needed for successful catheter placement, the cohort was divided into uncomplicated (group 1) and difficult (more than one attempt, group 2) catheterization cases. Cases subjected to primary ultrasound were excluded from the analysis.

Results:

Body weight, height and surface area (BSA) of patients in group 2 (n = 16) were significantly lower than those of patients in group 1 (n = 25), and internal RA diameters were significantly smaller in group 2 patients. In the whole cohort, BSA was significantly associated with distal and proximal internal RA diameters. In contrast, no differences were observed in the skin-to-artery distance, the longitudinal axis deviation (kinking) or blood flow velocity. Median time to successful catheterization was 77 (47-179) s. Prolonged time needed for cannulation was significantly associated with lower body weight, BMI and BSA, and with reduced distal and proximal internal RA diameter.

Conclusions:

RA catheterization performed through pulse palpation may be difficult, especially in adult patients with lower body weight and height, due to reduced arterial diameters. Initial use of ultrasound in these patients may reduce first-attempt failure, preventing procedural delays and patient discomfort.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article