Your browser doesn't support javascript.
loading
Clinical applications of photon counting detector CT.
McCollough, Cynthia H; Rajendran, Kishore; Baffour, Francis I; Diehn, Felix E; Ferrero, Andrea; Glazebrook, Katrina N; Horst, Kelly K; Johnson, Tucker F; Leng, Shuai; Mileto, Achille; Rajiah, Prabhakar Shantha; Schmidt, Bernhard; Yu, Lifeng; Flohr, Thomas G; Fletcher, Joel G.
Afiliação
  • McCollough CH; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA. mccollough.cynthia@mayo.edu.
  • Rajendran K; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Baffour FI; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Diehn FE; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Ferrero A; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Glazebrook KN; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Horst KK; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Johnson TF; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Leng S; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Mileto A; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Rajiah PS; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Schmidt B; Computed Tomography, Siemens Healthineers, Siemensstrasse 3, Forchheim, 91301, Germany.
  • Yu L; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
  • Flohr TG; Computed Tomography, Siemens Healthineers, Siemensstrasse 3, Forchheim, 91301, Germany.
  • Fletcher JG; Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Eur Radiol ; 33(8): 5309-5320, 2023 Aug.
Article em En | MEDLINE | ID: mdl-37020069
The X-ray detector is a fundamental component of a CT system that determines the image quality and dose efficiency. Until the approval of the first clinical photon-counting-detector (PCD) system in 2021, all clinical CT scanners used scintillating detectors, which do not capture information about individual photons in the two-step detection process. In contrast, PCDs use a one-step process whereby X-ray energy is converted directly into an electrical signal. This preserves information about individual photons such that the numbers of X-ray in different energy ranges can be counted. Primary advantages of PCDs include the absence of electronic noise, improved radiation dose efficiency, increased iodine signal and the ability to use lower doses of iodinated contrast material, and better spatial resolution. PCDs with more than one energy threshold can sort the detected photons into two or more energy bins, making energy-resolved information available for all acquisitions. This allows for material classification or quantitation tasks to be performed in conjunction with high spatial resolution, and in the case of dual-source CT, high pitch, or high temporal resolution acquisitions. Some of the most promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value. These include imaging of the inner ear, bones, small blood vessels, heart, and lung. This review describes the clinical benefits observed to date and future directions for this technical advance in CT imaging. KEY POINTS: • Beneficial characteristics of photon-counting detectors include the absence of electronic noise, increased iodine signal-to-noise ratio, improved spatial resolution, and full-time multi-energy imaging. • Promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value and applications requiring multi-energy data simultaneous with high spatial and/or temporal resolution. • Future applications of PCD-CT technology may include extremely high spatial resolution tasks, such as the detection of breast micro-calcifications, and quantitative imaging of native tissue types and novel contrast agents.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos de Iodo / Iodo Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos de Iodo / Iodo Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article