Your browser doesn't support javascript.
loading
Modified Isoinertial-Based Ruffier Test in Healthy Individuals: A Feasibility Study.
Trovato, Bruno; Roggio, Federico; Petrigna, Luca; Musumeci, Giuseppe.
Afiliação
  • Trovato B; Department of Biomedical and Biotechnological Sciences, Section of Anatomy, Histology and Movement Science, School of Medicine, University of Catania, Via S. Sofia n°97, 95123 Catania, Italy.
  • Roggio F; Department of Biomedical and Biotechnological Sciences, Section of Anatomy, Histology and Movement Science, School of Medicine, University of Catania, Via S. Sofia n°97, 95123 Catania, Italy.
  • Petrigna L; Sport and Exercise Sciences Research Unit, Department of Psychology, Educational Science and Human Movement, University of Palermo, Via Giovanni Pascoli 6, 90144 Palermo, Italy.
  • Musumeci G; Department of Biomedical and Biotechnological Sciences, Section of Anatomy, Histology and Movement Science, School of Medicine, University of Catania, Via S. Sofia n°97, 95123 Catania, Italy.
J Funct Morphol Kinesiol ; 8(2)2023 Mar 24.
Article em En | MEDLINE | ID: mdl-37092368
ABSTRACT
Cardiorespiratory fitness is an essential indicator in sports science and sports medicine that can be assessed with several tests. The Ruffier test is a submaximal test valid to estimate maximum oxygen uptake; it consists of 30 squats in 45 s, which may be challenging for inexperienced individuals. This study aims to verify the feasibility of a modified inertial-based version of the Ruffier test to assess cardiorespiratory fitness with 10 squats in 15 s. Both classic and isoinertial Ruffier tests were administered to thirty-five healthy young adults (20 men and 15 women), age 22.06 ± 2.13 years, BMI 23.87 ± 2.74. The two one-sided test confirmed the comparability of the isoinertial Ruffier test with its classic version within equivalence bounds of ±3.726. Furthermore, gender, age, body weight, the difference between peak heart rate after isoinertial squatting and resting heart rate, and the isoinertial Ruffier index are the coefficients of our best VO2max prediction model with an adjusted R2 of 0.937, sensitivity of 0.89, and specificity of 0.81. The study evidenced the feasibility of the isoinertial Ruffier test to measure cardiorespiratory fitness through a quick, safe, and short squat test easy to perform in fitness centers and primary care clinics.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article