Your browser doesn't support javascript.
loading
Mean 16-Year Results of Total Hip Arthroplasty With Alumina Ceramic Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years or Less.
Youngman, Tyler R; Verhotz, Daniel R; Layon, Daniel R; Parilla, Frank W; Pashos, Gail E; Thornton, Tanner; Bendich, Ilya; Clohisy, John C.
Afiliação
  • Youngman TR; Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri.
  • Verhotz DR; Peachtree Orthopedics, Atlanta, Georgia.
  • Layon DR; Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri.
  • Parilla FW; Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri.
  • Pashos GE; Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri.
  • Thornton T; Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri.
  • Bendich I; Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri.
  • Clohisy JC; Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri.
J Arthroplasty ; 38(7 Suppl 2): S346-S350, 2023 07.
Article em En | MEDLINE | ID: mdl-37105332
BACKGROUND: Highly cross-linked polyethylene (HXLPE) is a widely used bearing surface in total hip arthroplasty (THA); long-term results in young patients are limited. We previously demonstrated excellent results in HXPLE on cobalt-chrome femoral heads at 15-year mean follow-up. The purpose of the present study was to investigate polyethylene wear rates, implant survivorships, wear-related revisions, and patient-reported outcomes (PROs) in a young patient cohort who had alumina ceramic on HXPLE coupling at an average 16-year follow-up. METHODS: This was a retrospective study of 128 hips that underwent THA with HXLPE on alumina ceramic bearings between March 1, 2004, and April 15, 2007. The patient's mean age was 38 years (range, 13 to 50). All THAs utilized HXPLE liners with alumina ceramic heads. The University of California, Los Angeles activity score and modified Harris hip scores were collected preoperatively and at each follow-up. Martell hip analysis suite was used for wear calculations. RESULTS: At average 16 years (range, 13 to 18), aseptic revision survivorship was 93.3% and osteolysis/wear survivorship was 99.2%. The mean linear wear rate was 0.0191 mm/year and mean volumetric wear rate was 19.43 mm3/y, both of which were clinically undetectable. We observed excellent PROs with a significant increase in mean modified Harris hip scores (43.6 to 87.4, P < .0001) and the University of California, Los Angeles activity scores (4.0 to 6.0, P < .0001). There were no statistically significant differences in PROs or wear rates between ceramic and cobalt-chrome groups. CONCLUSION: At a mean 16-year follow-up, young patients who had HXLPE on ceramic coupling had excellent wear properties, PROs, and acceptable survivorships.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article