Your browser doesn't support javascript.
loading
Soft X-ray spectro-ptychography of boron nitride nanobamboos, carbon nanotubes and permalloy nanorods.
Vijayakumar, Jaianth; Yuan, Hao; Mille, Nicolas; Stanescu, Stefan; Swaraj, Sufal; Favre-Nicolin, Vincent; Najafi, Ebrahim; Hitchcock, Adam P; Belkhou, Rachid.
Afiliação
  • Vijayakumar J; Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint-Aubin, 91192 Gif-sur-Yvette Cedex, France.
  • Yuan H; Department of Electrical and Computer Engineering, University of Victoria, Victoria, BC, Canada V8W 2Y2.
  • Mille N; Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint-Aubin, 91192 Gif-sur-Yvette Cedex, France.
  • Stanescu S; Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint-Aubin, 91192 Gif-sur-Yvette Cedex, France.
  • Swaraj S; Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint-Aubin, 91192 Gif-sur-Yvette Cedex, France.
  • Favre-Nicolin V; ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble, France.
  • Najafi E; The Chemours Company, Wilmington, DE 19899, USA.
  • Hitchcock AP; Department of Electrical and Computer Engineering, University of Victoria, Victoria, BC, Canada V8W 2Y2.
  • Belkhou R; Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint-Aubin, 91192 Gif-sur-Yvette Cedex, France.
J Synchrotron Radiat ; 30(Pt 4): 746-757, 2023 Jul 01.
Article em En | MEDLINE | ID: mdl-37145139
ABSTRACT
Spectro-ptychography offers improved spatial resolution and additional phase spectral information relative to that provided by scanning transmission X-ray microscopes. However, carrying out ptychography at the lower range of soft X-ray energies (e.g. below 200 eV to 600 eV) on samples with weakly scattering signals can be challenging. Here, results of soft X-ray spectro-ptychography at energies as low as 180 eV are presented, and its capabilities are illustrated with results from permalloy nanorods (Fe 2p), carbon nanotubes (C 1s) and boron nitride bamboo nanostructures (B 1s, N 1s). The optimization of low-energy X-ray spectro-ptychography is described and important challenges associated with measurement approaches, reconstruction algorithms and their effects on the reconstructed images are discussed. A method for evaluating the increase in radiation dose when using overlapping sampling is presented.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article