Your browser doesn't support javascript.
loading
Reliability and Validity of the Malay BREAST-Q in Women Undergoing Breast Cancer Surgery in Malaysia.
Shunnmugam, Bairave; Islam, Tania; Sinnadurai, Siamala; Seng Hui, Chua; Mee Hong, See; Chinna, Karuthan; Aishah Mohd Taib, Nur.
Afiliação
  • Shunnmugam B; Department of Primary Care Medicine, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Islam T; Department of Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Sinnadurai S; Department of Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Seng Hui C; Department of Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Mee Hong S; Department of Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Chinna K; School of Medicine, Faculty of Health & Medical Sciences, Taylor's University, Subang Jaya, Malaysia.
  • Aishah Mohd Taib N; Department of Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
Asia Pac J Public Health ; 35(2-3): 129-135, 2023 03.
Article em En | MEDLINE | ID: mdl-37171249
ABSTRACT
This study aims to translate the BREAST-Q into Malay and validate it in breast cancer patients undergoing surgery. The English BREAST-Q was translated to Malay using the back-translation method. A total of 144 newly diagnosed breast cancer patients were sampled conveniently between December 2015 and November 2016. Test-retest was done after two to three weeks. Data were analyzed using SPSS and AMOS software. Content experts agreed the items in the Malay BREAST-Q were measuring the constructs appropriately. Internal consistencies were good for all items in each subscale (Cronbach's alpha = 0.83-0.95). The highest inter-item correlation for each item with at least one other item in the construct ranged from 0.47 to 0.90. The lowest corrected item-total correlation values ranged from 0.47 to 0.72. The test-retest analysis showed good reproducibility (intraclass correlation coefficient = 0.71-0.98). In exploratory factor analysis, the Kaiser-Meyer-Olkin values were excellent in all four subscales (0.76, 0.92, 0.91, and 0.86). For all subscales, the number of factors extracted cumulatively explained more than 50% of the variance. The Malay BREAST-Q demonstrated good reliability, face validity, content validity, and construct validity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama Limite: Female / Humans País/Região como assunto: Asia Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama Limite: Female / Humans País/Região como assunto: Asia Idioma: En Ano de publicação: 2023 Tipo de documento: Article