Your browser doesn't support javascript.
loading
Comparative Verification of the Accuracy of Implant Models Made of PLA, Resin, and Silicone.
Wakamori, Kana; Nagata, Koudai; Nakashizu, Toshifumi; Tsuruoka, Hayato; Atsumi, Mihoko; Kawana, Hiromasa.
Afiliação
  • Wakamori K; Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan.
  • Nagata K; Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan.
  • Nakashizu T; Division of the Dental Practice Support, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan.
  • Tsuruoka H; Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan.
  • Atsumi M; Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan.
  • Kawana H; Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, 82 Inaoka-cho, Yokosuka 238-8580, Japan.
Materials (Basel) ; 16(9)2023 Apr 23.
Article em En | MEDLINE | ID: mdl-37176189
Polylactic acid (PLA) has gained considerable attention as an alternative to petroleum-based materials due to environmental concerns. We fabricated implant models with fused filament fabrication (FFF) 3D printers using PLA, and the accuracies of these PLA models were compared with those of plaster models made from silicone impressions and resin models made with digital light processing (DLP). A base model was obtained from an impact-training model. The scan body was mounted on the plaster, resin, and PLA models obtained from the base model, and the obtained information was converted to stereolithography (STL) data by the 3D scanner. The base model was then used as a reference, and its data were superimposed onto the STL data of each model using Geomagic control. The horizontal and vertical accuracies of PLA models, as calculated using the Tukey-Kramer method, were 97.2 ± 48.4 and 115.5 ± 15.1 µm, respectively, which suggests that the PLA model is the least accurate among the three models. In both cases, significant differences were found between PLA and gypsum and between the PLA and resin models. However, considering that the misfit of screw-retained implant frames should be ≤150 µm, PLA can be effectively used for fabricating implant models.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article