Your browser doesn't support javascript.
loading
Comprehensive analysis of alkenones by reversed-phase HPLC-MS with unprecedented selectivity, linearity and sensitivity.
Liao, Sian; Liu, Xiao-Lei; Manz, Katherine E; Pennell, Kurt D; Novak, Joseph; Santos, Ewerton; Huang, Yongsong.
Afiliação
  • Liao S; Department of Chemistry, Brown University, 324 Brook Street, Providence, RI, 02912, USA.
  • Liu XL; School of Geosciences, University of Oklahoma, 100 E. Boyd Street, Norman, OK, 73019, USA.
  • Manz KE; School of Engineering, Brown University, 345 Brook Street, Providence, RI, 02912, USA.
  • Pennell KD; School of Engineering, Brown University, 345 Brook Street, Providence, RI, 02912, USA.
  • Novak J; Ocean Sciences Department, University of California, Santa Cruz, CA, 95064, USA.
  • Santos E; Department of Earth, Environmental and Planetary Sciences, Brown University, 324 Brook Street, Providence, RI, 02912, USA.
  • Huang Y; Department of Earth, Environmental and Planetary Sciences, Brown University, 324 Brook Street, Providence, RI, 02912, USA. Electronic address: yongsong_huang@brown.edu.
Talanta ; 260: 124653, 2023 Aug 01.
Article em En | MEDLINE | ID: mdl-37178676
ABSTRACT
Alkenones are among the most widely used paleotemperature biomarkers. Traditionally, alkenones are analyzed using gas chromatography-flame ionization detector (GC-FID), or GC-chemical ionization-mass spectrometry (GC-CI-MS). However, these methods encounter considerable challenges for samples that exhibit matrix interference or low concentrations, with GC-FID requiring tedious sample preparations and GC-CI-MS suffering from nonlinear response and a narrow linear dynamic range. Here we demonstrate that reversed-phase high pressure liquid chromatography-mass spectrometry (HPLC-MS) methods provide excellent resolution, selectivity, linearity and sensitivity for alkenones in complex matrices. We systematically compared the advantages and limitations of three mass detectors (quadrupole, Orbitrap, and quadrupole-time of flight) and two ionization modes (electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI)) for alkenone analyses. We demonstrate that ESI performs better than APCI as response factors of various unsaturated alkenones are similar. Among the three mass analyzers tested, orbitrap MS provided the lowest limit of detection (0.4, 3.8 and 8.6 pg injected masses for Orbitrap, qTOF and single quadrupole MS, respectively) and the widest linear dynamic range (600, 20 and 30 folds for Orbitrap, qTOF and single quadrupole MS, respectively). Single quadrupole MS operated in ESI mode provides accurate quantification of proxy measurements over a wide range of injection masses, and with its modest instrument cost, represents an ideal method for routine applications. Analysis of global core-top sediment samples confirmed the efficacy of HPLC-MS methods for the detection and quantification of paleotemperature proxies based on alkenones and their superiority over GC-based methods. The analytical method demonstrated in this study should also allow highly sensitive analyses of diverse aliphatic ketones in complex matrices.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article