Metrology of infrared superconducting bolometers with a backshort.
Rostem, K; Brown, A D; Colazo Petit, F A; Kent, R A; Kutyrev, A S; Lebair, S W; Sharp, E H; Wollack, E J.
Afiliação
  • Rostem K; National Aeronautics and Space Administration Goddard Space Flight Center, 8800 Greenbelt Rd, Greenbelt, Maryland 20771, USA.
  • Brown AD; National Aeronautics and Space Administration Goddard Space Flight Center, 8800 Greenbelt Rd, Greenbelt, Maryland 20771, USA.
  • Colazo Petit FA; National Aeronautics and Space Administration Goddard Space Flight Center, 8800 Greenbelt Rd, Greenbelt, Maryland 20771, USA.
  • Kent RA; National Aeronautics and Space Administration Goddard Space Flight Center, 8800 Greenbelt Rd, Greenbelt, Maryland 20771, USA.
  • Kutyrev AS; National Aeronautics and Space Administration Goddard Space Flight Center, 8800 Greenbelt Rd, Greenbelt, Maryland 20771, USA.
  • Lebair SW; National Aeronautics and Space Administration Goddard Space Flight Center, 8800 Greenbelt Rd, Greenbelt, Maryland 20771, USA.
  • Sharp EH; National Aeronautics and Space Administration Goddard Space Flight Center, 8800 Greenbelt Rd, Greenbelt, Maryland 20771, USA.
  • Wollack EJ; National Aeronautics and Space Administration Goddard Space Flight Center, 8800 Greenbelt Rd, Greenbelt, Maryland 20771, USA.
Rev Sci Instrum ; 94(5)2023 May 01.
Article em En | MEDLINE | ID: mdl-37227195
ABSTRACT
We present the detailed metrology of a superconducting Transition-Edge Sensor (TES) absorber-coupled bolometer array bonded to a variable-delay backshort to form an integral field unit. The backshort is shaped as a wedge to continuously vary the electrical phase delay of the bolometer absorber reflective termination across the array. This resonant absorber termination structure is used to define a spectral response over a 41 bandwidth in the far-infrared, from ∼30 to 120 µm. The metrology of the backshort-bolometer array hybrid was achieved with a laser confocal microscope and a compact cryogenic system that provides a well-defined thermal (radiative and conductive) environment for the hybrid when cooled to ∼10 K. The results show the backshort free-space delays do not change with cooling. The estimated backshort slope is 1.58 milli-radians and within 0.3% of the targeted value. The sources of error in the free-space delay of the hybrid and optical cryogenic metrology implementations are discussed in detail. We also present measurements of the bolometer's single-crystal silicon membrane topography. The membranes deform and deflect out-of-plane under both warm and cold conditions. Intriguingly, the optically active area of the membranes tends to flatten when cold and repeatably achieve the same mechanical state over many thermal cycles; hence, no evidence for thermally-induced mechanical instability is observed. Most of the cold deformation is sourced from thermally-induced stress in the metallic layers comprising the TES element of the bolometer pixels. These results provide important considerations for the design of ultra-low-noise TES bolometers.