Your browser doesn't support javascript.
loading
Added Breathing Resistance during Exercise Impairs Pulmonary Ventilation and Exaggerates Exercise-Induced Hypoxemia Leading to Impaired Aerobic Exercise Performance.
Han, Jean-Hee; Jang, Min-Hyeok; Kim, Dae-Hwan; Kim, Jung-Hyun.
Afiliação
  • Han JH; Department of Physical Education, General Graduate School, Kyung Hee University, Yongin-si 17104, Republic of Korea.
  • Jang MH; Department of Physical Education, General Graduate School, Kyung Hee University, Yongin-si 17104, Republic of Korea.
  • Kim DH; Department of Physical Education, General Graduate School, Kyung Hee University, Yongin-si 17104, Republic of Korea.
  • Kim JH; Department of Sports Medicine, Kyung Hee University, Yongin-si 17104, Republic of Korea.
Article em En | MEDLINE | ID: mdl-37239486
Protective masks impose variable breathing resistance (BR) on the wearer and may adversely affect exercise performance, yet existing literature shows inconsistent results under different types of masks and metabolic demands. The present study was undertaken to determine whether added BR impairs cardiopulmonary function and aerobic performance during exercise. Sixteen young healthy men completed a graded exercise test on a cycle ergometer under the four conditions of BR using a customized breathing resistor at no breathing resistance (CON), 18.9 (BR1), 22.2 (BR2), and 29.9 Pa (BR3). The results showed that BR significantly elevates respiratory pressure (p < 0.001) and impairs ventilatory response to graded exercise (reduced VE; p < 0.001) at a greater degree with an increased level of BR which caused mild to moderate exercise-induced hypoxemia (final mean SpO2: CON = 95.6%, BR1 = 94.4%, BR2 = 91.6%, and BR3 = 90.6%; p < 0.001). Especially, such a marked reduction in SpO2 was significantly correlated with maximal oxygen consumption at the volitional fatigue (r = 0.98, p < 0.001) together with exaggerated exertion and breathing discomfort (p < 0.001). In conclusion, added BR commonly experienced when wearing tight-fitting facemasks and/or respirators could significantly impair cardiopulmonary function and aerobic performance at a greater degree with an increasing level of BR.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Exercício Físico / Ventilação Pulmonar Limite: Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Exercício Físico / Ventilação Pulmonar Limite: Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article