Your browser doesn't support javascript.
loading
Cost-effectiveness of transcatheter aortic valve implantation in patients at low surgical risk in France: a model-based analysis of the Evolut LR trial.
Tchétché, Didier; de Gennes, Coline Dubois; Cormerais, Quentin; Geisler, Benjamin P; Dutot, Camille; Wilquin-Bequet, Fanny; Breau-Brunel, Manon; Lueza, Béranger; Pietzsch, Jan B.
Afiliação
  • Tchétché D; Clinique Pasteur, 45 Avenue de Lombez, 31300, Toulouse, France. dtchetche@clinique-pasteur.com.
  • de Gennes CD; Amaris, London, UK.
  • Cormerais Q; Medtronic, Plc, Dublin, Ireland.
  • Geisler BP; Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Dutot C; Wing Tech Inc., Menlo Park, CA, USA.
  • Wilquin-Bequet F; Medtronic, Plc, Dublin, Ireland.
  • Breau-Brunel M; Medtronic, Plc, Dublin, Ireland.
  • Lueza B; Amaris, London, UK.
  • Pietzsch JB; Amaris, London, UK.
Eur J Health Econ ; 25(3): 447-457, 2024 Apr.
Article em En | MEDLINE | ID: mdl-37254006
BACKGROUND: In the recent Evolut Low Risk randomized trial, transcatheter aortic valve implantation (TAVI) was shown to be non-inferior to surgery (SAVR) regarding the composite end point of all-cause mortality or disabling stroke at 24 months. AIMS: To evaluate the cost-effectiveness of self-expandable TAVI in low-risk patients, using the French healthcare system as the basis for analysis. METHODS: Mortality, health-related quality of life, and clinical event rates through two-year follow-up were derived from trial data (N = 725 TAVI and N = 678 SAVR; mean age: 73.9 years; mean STS-PROM: 1.9%). Cost inputs were based on real-world data for TAVI and SAVR procedures in the French healthcare system. Costs and effectiveness as quality-adjusted life years (QALYs) were projected to lifetime via a decision-analytic model under assumption of no mortality difference beyond two years. The discounted incremental cost-effectiveness ratio (ICER) was evaluated against a willingness-to-pay threshold of €50,000 per QALY gained. Deterministic and probabilistic sensitivity analyses were conducted, including assumptions about differential long-term survival. RESULTS: For the base case, mean survival was 13.69 vs 13.56 (+ 0.13) years for TAVI and SAVR, respectively. Discounted QALYs were 9.34 vs. 9.21 (+ 0.13) and discounted lifetime costs €52,267 vs. €51,433 (+ €833), resulting in a lifetime ICER of €6368 per QALY gained. In probabilistic sensitivity analysis, TAVI was found dominant or cost-effective in 74.4% of samples. CONCLUSION: TAVI in patients at low surgical risk is a cost-effective alternative to SAVR in the French healthcare system. Longer follow-up data will help increase the accuracy of lifetime survival projections.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Tipo de estudo: Clinical_trials / Etiology_studies / Health_economic_evaluation / Prognostic_studies / Risk_factors_studies Limite: Aged / Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Tipo de estudo: Clinical_trials / Etiology_studies / Health_economic_evaluation / Prognostic_studies / Risk_factors_studies Limite: Aged / Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2024 Tipo de documento: Article