Your browser doesn't support javascript.
loading
SAPM: Self-Adaptive Parallel Manipulator with Pose and Force Adjustment for Robotic Ultrasonography.
Bao, Xianqiang; Wang, Shuangyi; Zheng, Lingling; Housden, Richard James; Hajnal, Joseph; Rhode, Kawal.
Afiliação
  • Bao X; School of Biomedical Engineering & Imaging Sciences, King's College London, SE1 7EH, United Kingdom.
  • Wang S; State Key Laboratory of Management and Control for Complex Systems, Institute of Automation, Chinese Academy of Sciences, Beijing, 100190, China.
  • Zheng L; Faculty of Engineering and Design, Kagawa University, Takamatsu 761-0396, Japan.
  • Housden RJ; School of Biomedical Engineering & Imaging Sciences, King's College London, SE1 7EH, United Kingdom.
  • Hajnal J; School of Biomedical Engineering & Imaging Sciences, King's College London, SE1 7EH, United Kingdom.
  • Rhode K; School of Biomedical Engineering & Imaging Sciences, King's College London, SE1 7EH, United Kingdom.
IEEE Trans Ind Electron ; 70(10): 10333-10343, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37323755
ABSTRACT
Robotic ultrasonography potentially acts as an essential aid to medical diagnosis. To overcome the limitations in robotic ultrasonography, in this paper, we proposed a novel self-adaptive parallel manipulator (SAPM) that can automatically adjust the ultrasound (US) probe pose to adapt to various contours of scanned areas, provide approximate constant operating forces/torques, achieve mechanical measurement, and cushion undesired produced forces. A novel parallel adjustment mechanism is proposed to attain automatic pose adjustment with 3 degrees of freedom (DOFs). This mechanism enables the US probe to adapt to different scanned areas and to perform the scanning with approximate constant forces and torques. Besides, we present a mechanical measurement and safety protection method that can be integrated into the SAPM and used as operation status monitoring and early warning during scanning procedures by capturing operating forces and torques. Experiments were carried out to calibrate the measurement and buffer units and evaluate the performance of the SAPM. Experimental results show the ability of the SAPM to provide 3-DoFs motion and operating force/torque measurement and automatically adjust the US probe pose to capture US images of equally good quality compared to a manual sonographer scan. Moreover, it has characteristics similar to soft robots that could significantly improve operation safety, and could be extended to some other engineering or medical applications.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Ano de publicação: 2023 Tipo de documento: Article