Transcutaneous measurement of renal function in two rodent models of obstructive nephropathy.
BMC Res Notes
; 16(1): 119, 2023 Jun 26.
Article
em En
| MEDLINE
| ID: mdl-37365638
OBJECTIVE: Glomerular filtration rate (GFR) is a key indicator of renal function. In both clinical practice and pre-clinical research, serum levels of endogenous filtration markers, such as creatinine, are often used to estimate GFR. However, these markers often do not reflect minor changes in renal function. In this study, we therefore set out to evaluate the applicability of transcutaneous GFR (tGFR) measurements to monitor the changes in renal function, as compared to plasma creatinine (pCreatinine), in two models of obstructive nephropathy, namely unilateral ureteral obstruction (UUO) or bilateral ureteral obstruction followed by release (BUO-R) in male Wistar rats. RESULTS: UUO animals showed a significant reduction in tGFR compared to baseline; whereas pCreatinine levels were not significantly changed. In BUO animals, tGFR drops 24 h post BUO and remains lower upon release of the obstruction until day 11. Concomitantly, pCreatinine levels were also increased 24 h after obstruction and 24 h post release, however after 4 days, pCreatinine returned to baseline levels. In conclusion, this study revealed that the tGFR method is superior at detecting minor changes in renal function as compared to pCreatinine measurements.