Your browser doesn't support javascript.
loading
Analytical validation of quantitative SARS-CoV-2 subgenomic and viral load laboratory developed tests conducted on the Panther Fusion® (Hologic) with preliminary application to clinical samples.
Lakhal-Naouar, Ines; Hack, Holly R; Moradel, Edgar; Jarra, Amie; Grove, Hannah L; Ismael, Rani M; Padilla, Steven; Coleman, Dante; Ouellette, Jason; Darden, Janice; Storme, Casey; Peachman, Kristina K; Hall, Tara L; Huhtanen, Mark E; Scott, Paul T; Hakre, Shilpa; Jagodzinski, Linda L; Peel, Sheila A.
Afiliação
  • Lakhal-Naouar I; Diagnostics and Countermeasures Branch, Walter Reed Army Institute of Research, Silver Spring, Maryland, United States of America.
  • Hack HR; Diagnostics and Countermeasures Branch, Walter Reed Army Institute of Research, Silver Spring, Maryland, United States of America.
  • Moradel E; Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, Maryland, United States of America.
  • Jarra A; Diagnostics and Countermeasures Branch, Walter Reed Army Institute of Research, Silver Spring, Maryland, United States of America.
  • Grove HL; Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, Maryland, United States of America.
  • Ismael RM; Diagnostics and Countermeasures Branch, Walter Reed Army Institute of Research, Silver Spring, Maryland, United States of America.
  • Padilla S; Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, Maryland, United States of America.
  • Coleman D; Diagnostics and Countermeasures Branch, Walter Reed Army Institute of Research, Silver Spring, Maryland, United States of America.
  • Ouellette J; Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, Maryland, United States of America.
  • Darden J; Diagnostics and Countermeasures Branch, Walter Reed Army Institute of Research, Silver Spring, Maryland, United States of America.
  • Storme C; Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, Maryland, United States of America.
  • Peachman KK; Diagnostics and Countermeasures Branch, Walter Reed Army Institute of Research, Silver Spring, Maryland, United States of America.
  • Hall TL; Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, Maryland, United States of America.
  • Huhtanen ME; Diagnostics and Countermeasures Branch, Walter Reed Army Institute of Research, Silver Spring, Maryland, United States of America.
  • Scott PT; Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, Maryland, United States of America.
  • Hakre S; Diagnostics and Countermeasures Branch, Walter Reed Army Institute of Research, Silver Spring, Maryland, United States of America.
  • Jagodzinski LL; Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, Maryland, United States of America.
  • Peel SA; Diagnostics and Countermeasures Branch, Walter Reed Army Institute of Research, Silver Spring, Maryland, United States of America.
PLoS One ; 18(6): e0287576, 2023.
Article em En | MEDLINE | ID: mdl-37384714
ABSTRACT

OBJECTIVE:

Validate the performance characteristics of two analyte specific, laboratory developed tests (LDTs) for the quantification of SARS-CoV-2 subgenomic RNA (sgRNA) and viral load on the Hologic Panther Fusion® using the Open Access functionality.

METHODS:

Custom-designed primers/probe sets targeting the SARS-CoV-2 Envelope gene (E) and subgenomic E were optimized. A 20-day performance validation following laboratory developed test requirements was conducted to assess assay precision, accuracy, analytical sensitivity/specificity, lower limit of detection and reportable range.

RESULTS:

Quantitative SARS-CoV-2 sgRNA (LDT-Quant sgRNA) assay, which measures intermediates of replication, and viral load (LDT-Quant VLCoV) assay demonstrated acceptable performance. Both assays were linear with an R2 and slope equal to 0.99 and 1.00, respectively. Assay precision was evaluated between 4-6 Log10 with a maximum CV of 2.6% and 2.5% for LDT-Quant sgRNA and LDT-Quant VLCoV respectively. Using negative or positive SARS-CoV-2 human nasopharyngeal swab samples, both assays were accurate (kappa coefficient of 1.00 and 0.92). Common respiratory flora and other viral pathogens were not detected and did not interfere with the detection or quantification by either assay. Based on 95% detection, the assay LLODs were 729 and 1206 Copies/mL for the sgRNA and VL load LDTs, respectively.

CONCLUSION:

The LDT-Quant sgRNA and LDT-Quant VLCoV demonstrated good analytical performance. These assays could be further investigated as alternative monitoring assays for viral replication; and thus, medical management in clinical settings which could inform isolation/quarantine requirements.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: COVID-19 Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: COVID-19 Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article