Your browser doesn't support javascript.
loading
A Stable Phantom Material for Optical and Acoustic Imaging.
Hacker, Lina; Ivory, Aoife M; Joseph, James; Gröhl, Janek; Zeqiri, Bajram; Rajagopal, Srinath; Bohndiek, Sarah E.
Afiliação
  • Hacker L; Department of Physics, University of Cambridge; Cancer Research UK Cambridge Institute, University of Cambridge.
  • Ivory AM; Ultrasound and Underwater Acoustics Group, Department of Medical, Marine and Nuclear Physics, National Physical Laboratory.
  • Joseph J; School of Science and Engineering, University of Dundee; Centre for Medical Engineering and Technology, University of Dundee.
  • Gröhl J; Department of Physics, University of Cambridge; Cancer Research UK Cambridge Institute, University of Cambridge.
  • Zeqiri B; Ultrasound and Underwater Acoustics Group, Department of Medical, Marine and Nuclear Physics, National Physical Laboratory.
  • Rajagopal S; Ultrasound and Underwater Acoustics Group, Department of Medical, Marine and Nuclear Physics, National Physical Laboratory.
  • Bohndiek SE; Department of Physics, University of Cambridge; Cancer Research UK Cambridge Institute, University of Cambridge; seb53@cam.ac.uk.
J Vis Exp ; (196)2023 06 16.
Article em En | MEDLINE | ID: mdl-37395576
Establishing tissue-mimicking biophotonic phantom materials that provide long-term stability are imperative to enable the comparison of biomedical imaging devices across vendors and institutions, support the development of internationally recognized standards, and assist the clinical translation of novel technologies. Here, a manufacturing process is presented that results in a stable, low-cost, tissue-mimicking copolymer-in-oil material for use in photoacoustic, optical, and ultrasound standardization efforts. The base material consists of mineral oil and a copolymer with defined Chemical Abstract Service (CAS) numbers. The protocol presented here yields a representative material with a speed of sound c(f) = 1,481 ± 0.4 m·s-1 at 5 MHz (corresponds to the speed of sound of water at 20 °C), acoustic attenuation α(f) = 6.1 ± 0.06 dB·cm-1 at 5 MHz, optical absorption µa(λ) = 0.05 ± 0.005 mm-1 at 800 nm, and optical scattering µs'(λ) = 1 ± 0.1 mm-1 at 800 nm. The material allows independent tuning of the acoustic and optical properties by respectively varying the polymer concentration or light scattering (titanium dioxide) and absorbing agents (oil-soluble dye). The fabrication of different phantom designs is displayed and the homogeneity of the resulting test objects is confirmed using photoacoustic imaging. Due to its facile, repeatable fabrication process and durability, as well as its biologically relevant properties, the material recipe has high promise in multimodal acoustic-optical standardization initiatives.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Óleo Mineral / Diagnóstico por Imagem Tipo de estudo: Diagnostic_studies / Guideline Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Óleo Mineral / Diagnóstico por Imagem Tipo de estudo: Diagnostic_studies / Guideline Idioma: En Ano de publicação: 2023 Tipo de documento: Article