Discordance Between Invasive and NonInvasive Oxygen Saturation in Critically Ill COVID-19 Patients.
J Intensive Care Med
; 38(12): 1151-1157, 2023 Dec.
Article
em En
| MEDLINE
| ID: mdl-37415515
OBJECTIVES: To investigate discordance in oxy-hemoglobin saturation measured both by pulse oximetry (SpO2) and arterial blood gas (ABG, SaO2) among critically ill coronavirus disease 2019 (COVID-19(+)) patients compared to COVID-19(-) patients. METHODS: Paired SpO2 and SaO2 readings were collected retrospectively from consecutive adult admissions to four critical care units in the United States between March and May 2020. The primary outcome was the rate of discordance (|SaO2-SpO2|>4%) in COVID-19(+) versus COVID-19(-) patients. The odds each cohort could have been incorrectly categorized as having a PaO2/FiO2 above or below 150 by their SpO2: Fractional inhaled oxygen ratio (pulse oximetry-derived oxyhemoglobin saturation:fraction of inspired oxygen ratio [SF]) was examined. A multivariate regression analysis assessed confounding by clinical differences between cohorts including pH, body temperature, renal replacement therapy at time of blood draw, and self-identified race. RESULTS: There were 263 patients (173 COVID-19(+)) included. The rate of saturation discordance between SaO2 and SpO2 in COVID-19(+) patients was higher than in COVID-19(-) patients (27.9% vs 16.7%, odds ratio [OR] 1.94, 95% confidence interval [CI]: 1.11 to 2.27). The average difference between SaO2 and SpO2 for COVID-19(+) patients was -1.24% (limits of agreement, -13.6 to 11.1) versus -0.11 [-10.3 to 10.1] for COVID-19(-) patients. COVID-19(+) patients had higher odds (OR: 2.61, 95% CI: 1.14-5.98) of having an SF that misclassified that patient as having a PaO2:FiO2 ratio above or below 150. There was not an association between discordance and the confounders of pH, body temperature, or renal replacement therapy at time of blood draw. After controlling for self-identified race, the association between COVID-19 status and discordance was lost. CONCLUSIONS: Pulse oximetry was discordant with ABG more often in critically ill COVID-19(+) than COVID-19(-) patients. However, these findings appear to be driven by racial differences between cohorts.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Estado Terminal
/
COVID-19
Tipo de estudo:
Prognostic_studies
Limite:
Adult
/
Humans
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article