Intravoxel incoherent motion diffusion-weighted MRI for predicting the efficacy of high-intensity focused ultrasound ablation for uterine fibroids.
Jiang, Yu; Qin, Shize; Wang, Yanlin; Liu, Yang; Liu, Nian; Tang, Lingling; Fang, Jie; Jia, Qing; Huang, Xiaohua.
Afiliação
  • Jiang Y; Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China.
  • Qin S; Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China.
  • Wang Y; Department of Clinical Medicine, North Sichuan Medical College, Nanchong, China.
  • Liu Y; Department of Urology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China.
  • Liu N; Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China.
  • Tang L; Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China.
  • Fang J; Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China.
  • Jia Q; Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China.
  • Huang X; Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China.
Front Oncol ; 13: 1178649, 2023.
Article em En | MEDLINE | ID: mdl-37427113
ABSTRACT

Purpose:

To evaluate the significance of magnetic resonance (MR) intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) quantitative parameters in predicting early efficacy of high-intensity focused ultrasound (HIFU) ablation of uterine fibroids before treatment.

Method:

64 patients with 89 uterine fibroids undergoing HIFU ablation (51 sufficient ablations and 38 insufficient ablations) were enrolled in the study and completed MR imaging and IVIM-DWI before treatment. The IVIM-DWI parameters, including D (diffusion coefficient), D* (pseudo-diffusion coefficient), f (perfusion fraction) and relative blood flow (rBF) were calculated. The logistic regression (LR) model was constructed to analyze the predictors of efficacy. The receiver operating characteristic (ROC) curve was drawn to assess the model's performance. A nomograph was constructed to visualize the model.

Results:

The D value of the sufficient ablation group (931.0(851.5-987.4) × 10-6 mm2/s) was significantly lower than that of the insufficient ablation group (1052.7(1019.6-1158.7) × 10-6 mm2/s) (p<0.001). However, differences in D*, f, and rBF values between the groups were not significant (p>0.05). The LR model was constructed with D value, fibroid position, ventral skin distance, T2WI signal intensity, and contrast enhanced degree. The area under the ROC curve, specificity, and sensitivity of the model were 0.858 (95% confidence interval 0.781, 0.935), 0.686, and 0.947. The nomogram and calibration curves confirmed that the model had excellent performance.

Conclusion:

The IVIM-DWI quantitative parameters can be used to predict early effects of HIFU ablation on uterine fibroids. A high D value before treatment may indicate that the treatment will be less effective in the early stages.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article