Your browser doesn't support javascript.
loading
Analysis of the Overpressure Fields in a Shock Tube with Multi-Point Initiation.
Chen, Zhuo; Ren, Huiqi; Zhao, Qiang; Zhou, Songbai; Long, Zhilin; Liu, Wei.
Afiliação
  • Chen Z; School of Mechanical Engineering and Mechanics, Xiangtan University, Xiangtan 411105, China.
  • Ren H; Defense Engineering Institute, Academy of Military Sciences, People's Liberation Army of China, Luoyang 471023, China.
  • Zhao Q; Defense Engineering Institute, Academy of Military Sciences, People's Liberation Army of China, Luoyang 471023, China.
  • Zhou S; Defense Engineering Institute, Academy of Military Sciences, People's Liberation Army of China, Luoyang 471023, China.
  • Long Z; Defense Engineering Institute, Academy of Military Sciences, People's Liberation Army of China, Luoyang 471023, China.
  • Liu W; College of Civil Engineering, Xiangtan University, Xiangtan 411105, China.
Sensors (Basel) ; 23(10)2023 May 14.
Article em En | MEDLINE | ID: mdl-37430656
ABSTRACT
Shock tubes can carry out dynamic mechanical impact tests on civil engineering structures. The current shock tubes mostly use an explosion with aggregate charge to obtain shock waves. Limited effort has been made to study the overpressure field in shock tubes with multi-point initiation. In this paper, the overpressure fields in a shock tube under the conditions of single-point initiation, multi-point simultaneous initiation, and multi-point delayed initiation have been analyzed by combining experiments and numerical simulations. The numerical results match well with the experimental data, which indicates that the computational model and method used can accurately simulate the blast flow field in a shock tube. For the same charge mass, the peak overpressure at the exit of the shock tube with the multi-point simultaneous initiation is smaller than that with single-point initiation. As the shock waves are focused on the wall, the maximum overpressure on the wall of the explosion chamber near the explosion zone is not reduced. The maximum overpressure on the wall of the explosion chamber can be effectively reduced by a six-point delayed initiation. When the interval time is less than 10 ms, the peak overpressure at the nozzle outlet decreases linearly with the interval of the explosion. When the interval time is greater than 10 ms, the overpressure peak remains unchanged.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article