Your browser doesn't support javascript.
loading
A New Contactless Cross-Correlation Velocity Measurement System for Gas-Liquid Two-Phase Flow.
Sheng, Bixia; Huang, Junchao; Ji, Haifeng; Huang, Zhiyao.
Afiliação
  • Sheng B; State Key Laboratory of Industrial Control Technology, College of Control Science and Engineering, Zhejiang University, Hangzhou 310027, China.
  • Huang J; Xiaoshan District Committee of the Communist Youth League, Hangzhou 311222, China.
  • Ji H; State Key Laboratory of Industrial Control Technology, College of Control Science and Engineering, Zhejiang University, Hangzhou 310027, China.
  • Huang Z; College of Optical, Mechanical and Electrical Engineering, Zhejiang A&F University, Hangzhou 311300, China.
Sensors (Basel) ; 23(10)2023 May 19.
Article em En | MEDLINE | ID: mdl-37430800
ABSTRACT
Based on the principle of Contactless Conductivity Detection (CCD), a new contactless cross-correlation velocity measurement system with a three-electrode construction is developed in this work and applied to the contactless velocity measurement of gas-liquid two-phase flow in small channels. To achieve a compact design and to reduce the influence of the slug/bubble deformation and the relative position change on the velocity measurement, an electrode of the upstream sensor is reused as an electrode of the downstream sensor. Meanwhile, a switching unit is introduced to ensure the independence and consistency of the upstream sensor and the downstream sensor. To further improve the synchronization of the upstream sensor and the downstream sensor, fast switching and time compensation are also introduced. Finally, with the obtained upstream and downstream conductance signals, the velocity measurement is achieved by the principle of cross-correlation velocity measurement. To test the measurement performance of the developed system, experiments are carried out on a prototype with a small channel of 2.5 mm. The experimental results show that the compact design (three-electrode construction) is successful, and its measurement performance is satisfactory. The velocity range for the bubble flow is 0.312-0.816 m/s, and the maximum relative error of the flow rate measurement is 4.54%. The velocity range for the slug flow is 0.161 m/s-1.250 m/s, and the maximum relative error of the flow rate measurement is 3.70%.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article