Your browser doesn't support javascript.
loading
Development of a Methodology for Determination of Dioxins and Dioxin-like PCBs in Meconium by Gas Chromatography Coupled to High-Resolution Mass Spectrometry (GC-HRMS).
Lacomba, Iñaki; López, Antonio; Hervàs-Ayala, Raquel; Coscollà, Clara.
Afiliação
  • Lacomba I; Foundation for the Promotion of Health and Biomedical Research of the Valencian Region, FISABIO-Public Health, Av. Catalunya, 21, 46020 Valencia, Spain.
  • López A; Department of Analytical Chemistry, Univeristy of Valencia, Doctor Moliner 50, 46100 Burjassot, Spain.
  • Hervàs-Ayala R; Foundation for the Promotion of Health and Biomedical Research of the Valencian Region, FISABIO-Public Health, Av. Catalunya, 21, 46020 Valencia, Spain.
  • Coscollà C; Department of Obstetrics and Gynaecology, General University Hospital of Valencia, 46014 Valencia, Spain.
Molecules ; 28(13)2023 Jun 26.
Article em En | MEDLINE | ID: mdl-37446668
ABSTRACT
An analytical strategy was applied to investigate polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dl-PCBs) in newborn meconium samples. The methodology includes extraction by selective pressurized liquid extraction (SPLE), followed by a clean-up multicolumn step. The samples were injected by gas chromatography coupled to a high-resolution mass spectrometer (GC-HRMS). The surrogate recoveries ranged from 68% to 95%, and the average of the limit of quantification (LOQ) ranged from 0.03 to 0.08 pg g-1 wet weight (ww) for PCDD/Fs and 0.2 to 0.88 pg g-1 ww for dl-PCBs. The strategy was applied to 10 samples collected in Valencia (Spain) in 2022. In total, 18 out of 29 analysed congeners were detected in at least one sample, whereas 6 of them were detected in all the samples (OCDD, PCB-123, PCB-118, PCB-105, PCB-167, and PCB-156). The levels for the sum of the 17 congeners of PCDD/Fs and 12 congeners of dl-PCBs in the upper-bound (UB), expressed as picograms of toxic equivalency quantity (TEQ) per gram of ww, ranged from 0.19 to 0.31 pg TEQ g-1 ww.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Benzofuranos / Bifenilos Policlorados / Dioxinas / Dibenzodioxinas Policloradas Limite: Humans / Newborn Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Benzofuranos / Bifenilos Policlorados / Dioxinas / Dibenzodioxinas Policloradas Limite: Humans / Newborn Idioma: En Ano de publicação: 2023 Tipo de documento: Article