Your browser doesn't support javascript.
loading
Systematic Workflow and Electrogram guidance to reduce X-ray Exposure Time during cryoballoon ablation of atrial fibrillation: the SWEET-Cryo strategy.
Rodríguez Muñoz, Daniel; Marco Del Castillo, Álvaro; Rajjoub Al-Mahdi, Ez Alddin; Lázaro Rivera, Carla; Guisasola Cienfuegos, María; Ramos Jiménez, Javier; Borrego Bernabé, Luis; Arribas Ynsaurriaga, Fernando; Salguero-Bodes, Rafael.
Afiliação
  • Rodríguez Muñoz D; Cardiology Department, Hospital Universitario 12 de Octubre, Av. de Córdoba, s/n, 28041 Madrid, Spain.
  • Marco Del Castillo Á; Instituto de Investigación Hospital 12 de Octubre (imas12), Av. de Córdoba, s/n, 28041 Madrid, Spain.
  • Rajjoub Al-Mahdi EA; Cardiology Department, Hospital Universitario 12 de Octubre, Av. de Córdoba, s/n, 28041 Madrid, Spain.
  • Lázaro Rivera C; Instituto de Investigación Hospital 12 de Octubre (imas12), Av. de Córdoba, s/n, 28041 Madrid, Spain.
  • Guisasola Cienfuegos M; Cardiology Department, Hospital Universitario 12 de Octubre, Av. de Córdoba, s/n, 28041 Madrid, Spain.
  • Ramos Jiménez J; Instituto de Investigación Hospital 12 de Octubre (imas12), Av. de Córdoba, s/n, 28041 Madrid, Spain.
  • Borrego Bernabé L; Cardiology Department, Hospital Universitario Fundación Jiménez Díaz, Av. de los Reyes Católicos, 2, 28040 Madrid, Spain.
  • Arribas Ynsaurriaga F; Cardiology Department, Hospital Universitario Central de Asturias, Av. Roma, s/n, 33011 Oviedo, Asturias, Spain.
  • Salguero-Bodes R; Cardiology Department, Hospital Universitario 12 de Octubre, Av. de Córdoba, s/n, 28041 Madrid, Spain.
Europace ; 25(9)2023 08 02.
Article em En | MEDLINE | ID: mdl-37497862
AIMS: Cryoballoon pulmonary vein isolation (CB-PVI) offers similar efficacy to point-by-point radiofrequency PVI for patients with atrial fibrillation (AF), but generally with higher X-ray exposure. Strategies aimed at reducing fluoroscopy mostly rely on other costly imaging techniques, limiting their applicability. We designed a Systematic Workflow and Electrogram guidance to reduce X-ray Exposure Time during CB-PVI (SWEET-Cryo) strategy and analysed its impact on fluoroscopy use and acute procedural and clinical outcomes. METHODS AND RESULTS: We enrolled 100 patients with paroxysmal or persistent AF undergoing CB-PVI by two operators with different levels of expertise. Patients treated with the SWEET-Cryo strategy (prospective cohort; n = 50) or conventional fluoroscopy (retrospective control cohort; n = 50) were compared. When applied by the senior operator, the SWEET-Cryo strategy significantly reduced the mean fluoroscopy time (FT) (2.6 ± 1.25 vs. 20.3 ± 10.8 min) and mean dose area product (DAP) (5.1 ± 3.8 vs. 35.3 ± 22.3 Gy cm2) compared with those of the control group, respectively (P < 0.001). Significant reductions in FT (6.4 ± 2.5 min vs. 32.5 ± 10.05) and DAP (13.9 ± 7.7 vs. 92.3 ± 63.8) were also achieved by the less experienced operator (P < 0.001). No difference was observed in acute and long-term complications or freedom from AF between fluoroscopy strategies during a 33-month median follow-up. Mean FT was maintained below 3 min in randomly selected cases performed during the follow-up period. CONCLUSION: In contrast to conventional protocols and regardless of the operator's experience, the optimized SWEET-Cryo strategy dramatically reduced fluoroscopy exposure during CB-PVI. The efficacy, safety, or added costs of the ablation procedure were not compromised.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Ablação por Cateter / Criocirurgia Tipo de estudo: Guideline / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Ablação por Cateter / Criocirurgia Tipo de estudo: Guideline / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article